Home › Power Source / Network › 3ZR-FAE BATTERY / CHARGING › CHARGING SYSTEM › from 2015.10
RM3090E _57 Power Source / Network _008394 3ZR-FAE BATTERY / CHARGING _0046852 CHARGING SYSTEM G

3ZR-FAE BATTERY / CHARGING  CHARGING SYSTEM  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

NOTICE:

If the battery is weak or if the engine is difficult to start, recharge the battery and perform inspections again before returning the vehicle to the customer.


PROCEDURE

Hide 1. CHECK BATTERY CONDITION

a.

Check the battery for damage or deformation. If severe damage, deformation or leakage is found, replace the battery.


b.
A116907

Check the electrolyte level in each cell.

·

If the electrolyte level is below the lower line, add distilled water to each cell. Then, recharge the battery and check the electrolyte specific gravity.

Standard specific gravity:

1.25 to 1.29 at 20°C (68°F)


·

If the electrolyte level is above the lower line, check the battery voltage when cranking the engine. If the battery voltage is less than 9.6 V, recharge or replace the battery.

HINT:

Before checking the battery voltage, turn off all the electrical systems (headlights, blower motor, rear window defogger, etc.).




c.

Check the voltage.

i.

Turn the ignition switch off and turn on the headlights for 20 to 30 seconds. This will remove the surface charge from the battery.


ii.

Measure the battery voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
Positive (+) terminal - Negative (-) terminal 20°C (68°F) 12.6 to 12.8 V


If the result is not as specified, recharge or replace the battery.



Hide 28800 2.REPLACE BATTERY (WITH ENGINE STOP AND START SYSTEM)

a.

Replace the battery.

NOTICE:

Use a battery specified for use with the stop and start system and an equivalent battery. If an unsupported battery is used, stop and start system functions maybe restricted to protect the battery.

Also, battery performance may decrease and the engine may not be able to restart.

Battery Type
Q-85 type or higher performance battery



Hide 3.INSPECT BATTERY TERMINAL, BATTERY STATE SENSOR ASSEMBLY AND FUSIBLE LINK AND FUSE

a.

Check whether the battery terminals and engine wire harness are loose or corroded.


b.

Check whether the battery state sensor assembly is deformed or cracked.

Torque:
Positive (+) Battery Terminal : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Negative (-) Battery Terminal (Battery State Sensor Assembly) : 5.4 N*m (55 kgf*cm, 48 in.*lbf)
Wire Harness : 7.6 N*m (77 kgf*cm, 67 in.*lbf)


c.

Measure the resistance of the fuses.

Standard resistance:

Below 1 Ω


If the result is not as specified, replace the fuse.


Hide 5.INSPECT GENERATOR WIRING

a.

Visually check the generator wiring.

i.

Check that the wiring is in good condition.



Hide 6.CHECK FOR ABNORMAL NOISE

a.

Check for abnormal noises from the generator assembly.

i.

Check that no abnormal noises are heard from the generator assembly while the engine is running.

If noise occurs, refer to Problem Symptoms Table.

Click herePower Source / Network>3ZR-FAE BATTERY / CHARGING>CHARGING SYSTEM>PROBLEM SYMPTOMS TABLE



Hide 7.INSPECT CHARGE WARNING LIGHT CIRCUIT

a.

Check that nothing is displayed on the multi-information display.


Hide 8.INSPECT CHARGING CIRCUIT WITHOUT LOAD

a.
A325166C02
2.313,1.927 2.531,0.448 2.531,0.448 2.719,0.448 false 0.344,2.208 0.656,2.406 0.313,0.198 10 false *1 2.542,2.24 2.854,2.438 0.313,0.198 10 false *2 2.771,0.365 3.083,0.563 0.313,0.198 10 false *a
*1 Battery
*2 Generator Assembly
*a Terminal B


Connect a voltmeter and an ammeter to the charging circuit as follows.

HINT:

If a battery/generator assembly tester is available, connect the tester to the charging circuit in accordance with the manufacturer's instructions.


i.

Disconnect the wire from terminal B of the generator assembly and connect it to the negative (-) lead of the ammeter.


ii.

Connect the ammeter positive (+) lead to terminal B of the generator assembly.


iii.

Connect the voltmeter positive (+) lead to terminal B of the generator assembly.


iv.

Ground the voltmeter negative (-) lead.



b.

Check the charging circuit.

i.

Maintain the engine speed at 2000 rpm and check the readings on the ammeter and voltmeter.

Standard Current:

10 A or higher


Standard Voltage:

13.2 to 14.8 V


If the result is not as specified, repair or replace the generator assembly.



Hide 9.INSPECT CHARGING CIRCUIT WITH LOAD

a.

With the engine running at 2000 rpm, turn the high beam headlights on and turn the heater blower switch to the "HI" position.


b.

Check the reading on the ammeter.

Standard Current:

30 A or higher


If the result is not as specified, repair or replace the generator assembly.

HINT:

If the battery is fully charged, the reading will sometimes be less than the standard. If this is the case, add more electrical load (operate the wipers, rear window defogger, etc.) and check the reading on the ammeter again.



Hide 10.INSPECT CHARGING SYSTEM

a.

Check the harness and connector.

i.

Disconnect the B93 ECM connector.


ii.

Disconnect the B90 generator assembly connector.


iii.

Disconnect the A75 battery state sensor assembly connector.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B93-61 (LIN) - B90-2 (LIN) Always Below 1 Ω
B93-61 (LIN) or B90-2 (LIN) - Body ground Ignition switch off
(while LIN communication is stopped)
10 kΩ or higher
B93-61 (LIN) - A75-2 (LIN) Always Below 1 Ω
B93-61 (LIN) or A75-2 (LIN) - Body ground Ignition switch off
(while LIN communication is stopped)
10 kΩ or higher


If the result is not as specified, repair or replace the harness or connector.