Home › Power Source / Network › 3ZR-FE BATTERY / CHARGING › CHARGING SYSTEM › from 2015.10
RM3090E _57 Power Source / Network _008412 3ZR-FE BATTERY / CHARGING _0046986 CHARGING SYSTEM C

3ZR-FE BATTERY / CHARGING  CHARGING SYSTEM  P161A  Lost Communication with Alternator  


DESCRIPTION

The ECM and generator assembly each detect reception malfunctions. A generator assembly reception malfunction detected by the generator assembly is sent to the ECM via LIN communication. If there is a malfunction in either the ECM or generator assembly, the ECM determines that there is a LIN communication malfunction and outputs a DTC.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory
P161A Lost Communication with Alternator Diagnosis condition: Ignition switch to ON
When the ECM cannot receive LIN communication, the generator assembly cannot receive LIN communication for approximately 17 minutes or more.
Other: 1 trip
·

Generator assembly

·

ECM

·

Wire harness or connector


DTC stored

WIRING DIAGRAM

E221308E18
1.792,0.833 2.25,1.031 0.458,0.198 10 false 2 0.615,1.667 1.073,1.865 0.458,0.198 10 false B90 1.458,1.021 1.917,1.219 0.458,0.198 10 false LIN 0.667,1.833 2,2.083 1.333,0.25 10 false Generator Assembly 5.375,0.833 5.833,1.031 0.458,0.198 10 false 61 5.667,1.031 6.125,1.229 0.458,0.198 10 false LIN 5.833,1.833 6.292,2.031 0.458,0.198 10 false B93 5.833,2 6.292,2.198 0.458,0.198 10 false ECM 0.917,2.354 2.542,2.552 1.625,0.198 10 false : LIN Communication Line

PROCEDURE

1.CHECK CHARGING SYSTEM

Result:
Result
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)

NG

REPAIR OR REPLACE CHARGING SYSTEM

2.CHECK HARNESS AND CONNECTOR (ECM - GENERATOR ASSEMBLY)
a.

Disconnect the B93 ECM connector.


b.

Disconnect the B90 generator assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
B93-61 (LIN) - B90-2 (LIN) Always Below 1 Ω
B93-61 (LIN) or B90-2 (LIN) - Body ground Ignition switch off
(while LIN communication is stopped)
10 kΩ or higher



Result:
Proceed to
OK
NG



OK

3.INSPECT GENERATOR ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR