Home › Power Source / Network › 2WW BATTERY / CHARGING › BATTERY CURRENT SENSOR › from 2015.10
RM3090E _57 Power Source / Network _044381 2WW BATTERY / CHARGING _0233615 BATTERY CURRENT SENSOR A

2WW BATTERY / CHARGING  BATTERY CURRENT SENSOR  REMOVAL  


PROCEDURE

Hide 1. PRECAUTION

NOTICE:

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


Hide 28850 2.REMOVE GENERATOR CONTROL ECU ASSEMBLY

a.
A300510N01
1.281,0.063 1.438,0.26 0.156,0.198 10 A 2,0.438 2.156,0.635 0.156,0.198 10 B

Remove nut B and disconnect the wire harness from the generator control ECU assembly.

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION



b.

Disconnect the connector from the generator control ECU assembly.


c.

Remove nut A and disconnect the generator contol ECU assembly from the negative (-) battery terminal.


d.

Loosen the nut and remove the negative (-) battery terminal from the battery.