WINDOW / GLASS  POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)  Driver Side Power Window Auto Up / Down Function does not Operate with Power Window Master Switch  


DESCRIPTION

If the manual up and down function operates normally but the auto up and down function does not, then fail-safe mode may be functioning.

If power window initialization has not been performed, the auto up and down function will not operate.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>INITIALIZATION

WIRING DIAGRAM

B341195E01
2.563,3.49 4.479,3.833 1.917,0.344 10 Front Power Window Regulator Motor Assembly LH*1 2.552,4.146 4.479,4.49 1.927,0.344 10 Front Power Window Regulator Motor Assembly RH*2 2.573,3.302 4.104,3.5 1.531,0.198 10 J3*1, I3*2 1.875,1.885 2.792,2.083 0.917,0.198 10 DOOR D 3.802,1.594 4.417,1.792 0.615,0.198 10 AUTO 0.448,1.719 2.281,1.917 1.833,0.198 10 from Battery 0.031,0.667 1.865,0.865 1.833,0.198 10 from POWER Relay 1.823,0.854 3.052,1.052 1.229,0.198 10 P/W MAIN 3.75,2.354 4.365,2.552 0.615,0.198 10 DOWN 0.24,3.76 1.927,3.958 1.688,0.198 10 *1: for LHD 0.24,4.229 1.927,4.427 1.688,0.198 10 *2: for RHD 5.406,0.646 5.563,0.844 0.156,0.198 10 B 2.844,1.583 3,1.781 0.156,0.198 10 B 2.615,1.604 2.771,1.802 0.156,0.198 10 2 3.875,2.729 4.49,2.927 0.615,0.198 10 GND 3.969,1.958 4.583,2.156 0.615,0.198 10 UP 5.438,1.677 5.594,1.875 0.156,0.198 10 A 5.427,2.063 5.583,2.26 0.156,0.198 10 U 5.427,2.427 5.583,2.625 0.156,0.198 10 D 5.438,2.823 5.594,3.021 0.156,0.198 10 E 5.156,0.521 5.313,0.719 0.156,0.198 10 6 5.198,1.583 5.354,1.781 0.156,0.198 10 4 5.177,2.354 5.333,2.552 0.156,0.198 10 5 4.792,1.958 5.615,2.177 0.823,0.219 10 8*1, 1*2 5.375,3.302 6.906,3.5 1.531,0.198 10 J5*1, I5*2 5.333,3.5 7.031,4.396 1.698,0.896 10 Power Window Regulator Master Switch Assembly 4.792,2.729 5.75,2.917 0.958,0.188 10 1*1, 9*2 4.292,1.573 4.448,1.771 0.156,0.198 10 4 4.292,1.969 4.583,2.156 0.292,0.188 10 10 4.292,2.354 4.448,2.552 0.156,0.198 10 7 4.281,2.74 4.438,2.938 0.156,0.198 10 1

CAUTION / NOTICE / HINT

NOTICE:
·

Inspect the fuses for circuits related to this system before performing the following procedure.

·

The power window control system uses the LIN communication system. Inspect the communication function by following How to Proceed with Troubleshooting. Troubleshoot the power window control system after confirming that the communication system is functioning properly.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>HOW TO PROCEED WITH TROUBLESHOOTING

·

If the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) has been replaced with a new one, initialize the power window control system.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>INITIALIZATION

·

When the ECU determines that the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) has a malfunction, DTC B2311 is stored.

·

After the catch protection function operates, the auto operation is not performed the first time auto up is performed. All auto up operations performed after the first operate normally.



HINT:

If the pulse sensor built into the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD) is malfunctioning, the power window control system enters fail-safe mode. The remote up and down function cannot be operated during fail-safe mode. However, the power window can be closed by holding the power window regulator master switch assembly at the auto up position, and opened manually by pushing down the power window regulator master switch assembly.


PROCEDURE

1.READ VALUE USING GTS
a.

Read the Data List according to the display on the GTS.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>DATA LIST / ACTIVE TEST

Body Electrical > D-Door Motor > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
D Door P/W Auto SW Driver door power window auto switch signal ON or OFF ON: Driver door power window auto switch being operated
OFF: Driver door power window auto switch not being operated
-
Body Electrical > D-Door Motor > Data List
Tester Display
D Door P/W Auto SW
50003 124 1

Result:
Proceed to
On the GTS screen, ON or OFF is displayed accordingly
On the GTS screen, ON or OFF is not displayed accordingly



On the GTS screen, ON or OFF is displayed accordingly

2.PERFORM INITIALIZATION

On the GTS screen, ON or OFF is not displayed accordingly

4.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
2.PERFORM INITIALIZATION
a.

Initialize the front power window regulator motor assembly LH (for LHD) or front power window regulator motor assembly RH (for RHD).

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>INITIALIZATION


Result:
Proceed to
NEXT



NEXT

3.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
3.CHECK POWER WINDOW CONTROL SYSTEM (AUTO UP/DOWN FUNCTION)
a.

Check that the driver door power window moves when the auto up and down function of the power window regulator master switch assembly is operated.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW CONTROL SYSTEM(w/ Jam Protection Function)>OPERATION CHECK

OK:

Driver door auto up and down function is normal.



Result:
Proceed to
OK
NG (for LHD)
NG (for RHD)



OK

END (PROBLEM DUE TO INITIALIZATION FAILURE)

NG (for LHD)

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

NG (for RHD)

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

4.INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
a.

Remove the power window regulator master switch assembly.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH>REMOVAL


b.

Inspect the power window regulator master switch assembly.

Click hereVehicle Exterior>WINDOW / GLASS>POWER WINDOW MASTER SWITCH>INSPECTION


Result:
Proceed to
OK (for LHD)
OK (for RHD)
NG



OK (for LHD)

5.CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH)

OK (for RHD)

6.CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH)

NG

REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY

5.CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH)
a.

Disconnect the J5 power window regulator master switch assembly connector.


b.

Disconnect the J3 front power window regulator motor assembly LH connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
J5-4 (A) - J3-4 (AUTO) Always Below 1 Ω
J5-4 (A) or J3-4 (AUTO) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH)
a.

Disconnect the I5 power window regulator master switch assembly connector.


b.

Disconnect the I3 front power window regulator motor assembly RH connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
I5-4 (A) - I3-4 (AUTO) Always Below 1 Ω
I5-4 (A) or I3-4 (AUTO) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR