AIR CONDITIONING AMPLIFIER ASSEMBLY
| *A | w/o Front Seat Heater System | *B | w/ Front Seat Heater System |
Disconnect the G46 air conditioning amplifier assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G46-5 (B) - Body ground | G - Body ground | Power source (Back-up) | Power switch off | 11 to 14 V |
| G46-6 (IG+) - Body ground | GR - Body ground | Power source (IG) | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| G46-17 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
Reconnect the G46 air conditioning amplifier assembly connector.
Measure the voltage, resistance and pulse according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G47-1 (TAM) - G47-14 (SG-2) | R - R*1
R - GR*2 |
Ambient temperature sensor signal | ·
Power switch on (IG) (do not start the engine and electric motor) ·
Ambient temperature: 25°C (77°F) |
1.05 to 1.45 V |
·
Power switch on (IG) (do not start the engine and electric motor) ·
Ambient temperature: 40°C (104°F) |
0.64 to 0.87 V | |||
| G47-3 (SG-1) - Body ground | G - Body ground | Ground for sensor | Always | Below 1 Ω |
| G47-5 (TR) - Body ground | GR - Body ground | Room temperature sensor signal | ·
Power switch on (IG) ·
Cabin temperature: 25°C (77°F) |
1.05 to 1.45 V |
·
Power switch on (IG) ·
Cabin temperature: 40°C (104°F) |
0.64 to 0.87 V | |||
| G47-6 (PRE) - G47-15 (SG-4) | GR - L | Air conditioner pressure sensor signal | ·
Power switch on (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Normal pressure (below 3025 kPa [30.8 kgf/cm2, 439 psi] and higher than 176 kPa [1.8 kgf/cm2, 26 psi]) |
0.74 to 4.61 V |
·
Power switch on (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (less than 176 kPa (1.8 kgf/cm2, 26 psi)) |
Below 0.74 V | |||
·
Power switch on (READY) ·
Air conditioning system operating ·
Refrigerant pressure: Abnormal pressure (more than 3025 kPa (30.8 kgf/cm2, 439 psi)) |
4.61 V or higher | |||
| G47-11 (S5-3) - Body ground | L - Body ground | Power source of sensor | Power switch off → on (IG) | Below 1 V → 4.75 to 5.25 V |
| G47-14 (SG-2) - Body ground | R - Body ground*1
GR - Body ground*2 |
Ground for sensor | Always | Below 1 Ω |
| G47-15 (SG-4) - Body ground | L - Body ground | Ground for sensor | Always | Below 1 Ω |
| G46-4 (CANL) | - | CAN communication line | - | - |
| G46-5 (CANH) | - | CAN communication line | - | - |
| G46-7 (LIN1) - Body ground | BE - Body ground | LIN communication signal | Power switch on (IG) | Pulse generation
(See waveform 1) |
| G46-11 (ECOS) - Body ground | W - Body ground | Integration control and panel assembly (ECO switch) signal | ·
Power switch on (IG) ·
Integration control and panel assembly (ECO switch) Off → On |
11 to 14 V → Below 1 V |
| G46-21 (BLW) - Body ground | Y - Body ground | Blower motor speed control signal | ·
Power switch on (IG) ·
Blower switch: LO |
Pulse generation
(See waveform 2) |
| z11-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 Ω |
| z11-3 (BUS) - z11-2 (BUS G) | - | BUS IC control signal | Power switch on (IG) | Pulse generation
(See waveform 3) |
| z11-4 (B BUS) - z11-2 (BUS G) | - | Power supply for BUS IC | Power switch off | 11 to 14 V |
| z11-5 (SGA) - Body ground | - | Ground for No. 1 cooler thermistor | Always | Below 1 Ω |
| z11-6 (TEA) - z11-5 (SGA) | - | No. 1 cooler thermistor signal | ·
Power switch on (IG) ·
Evaporator temperature: 0°C (32°F) |
1.7 to 2.1 V |
·
Power switch on (IG) ·
Evaporator temperature: 15°C (59°F) |
0.9 to 1.3 V |
*1: for LHD
*2: for RHD
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | G46-7 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 μs./DIV. |
| Vehicle Condition | Power switch on (IG) |
Waveform 2:
| Item | Content |
|---|---|
| Terminal No. | G46-21(BLW) - Body ground |
| Tool Setting | 1 V/DIV., 500 μs./DIV. |
| Vehicle Condition | ·
Power switch on (IG) ·
Blower switch: LO |
Waveform 3:
| Item | Content |
|---|---|
| Terminal No. | z11-3 (BUS) - z11-2 (BUS G) |
| Tool Setting | 2 V/DIV., 20 μs./DIV. |
| Vehicle Condition | Power switch on (IG) |
AIR CONDITIONING CONTROL ASSEMBLY
Disconnect the G24 air conditioning control assembly connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G24-13 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| G24-9 (IG+) - Body ground | LA-B - Body ground | Power source (IG) | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V |
Reconnect the G24 air conditioning control assembly connector.
Check for waveform according to the value(s) in the table below.
| Terminal No.
(Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G24-7 (LIN1) - Body ground | LG - Body ground | LIN communication | Power switch on (IG) | Pulse generation
(See waveform 1) |
Waveform 1:
| Item | Content |
|---|---|
| Terminal No. | G24-7 (LIN1) - Body ground |
| Tool Setting | 2 V/DIV., 20 μs./DIV. |
| Vehicle Condition | Power switch on (IG) |
HYBRID VEHICLE CONTROL ECU ASSEMBLY
MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU)
Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM>TERMINALS OF ECU