If the cooling air is poor (cooling air is discharged), the following causes are possible.
| Malfunction Status | Factor |
|---|---|
·
Cooling is poor. ·
Takes time to cool down. |
·
ECO drive mode function (air flow volume is restricted due to ECO drive mode being selected) ·
Compressor with pulley assembly malfunction ·
Excessive refrigerant ·
Lack of refrigerant gas ·
Dirty cooler condenser ·
Cooling fan system malfunction ·
Air mix damper and link operation (jamming) ·
Automatic light control sensor (for Automatic Air Conditioning System) ·
Warm air flow |
Confirm setup of the ECO drive mode and turn it off if it is on.
When ECO drive mode is on, the air conditioning amplifier assembly ensures a minimum level of air conditioning control based on certain conditions, thereby contributing to improved fuel efficiency. Accordingly, explain to customers that the air volume will be weaker in these situations.
| Control | Control Summary |
|---|---|
| Airflow Control | Automatically switches the air inlet port to the internal air circulation mode when the outside air temperature is equal to or higher than a predetermined temperature and reduces the power consumption. |
| Air Inlet Control | Sets the blower level in AUTO mode lower than normal, and suppresses the power consumption. |
If integration control and panel assembly (ECO switch) is malfunctioning, perform diagnosis on the ECO switch circuit.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Regulator Pressure Sensor | Air conditioner pressure sensor | Min.: -0.4566 MPaG (gauge)
Max.: 3.2943 MPaG (gauge) |
Actual refrigerant pressure displayed | ·
Refrigerant line (gas leak etc.) ·
Air conditioner pressure sensor system malfunction |
| Tester Display |
|---|
| Regulator Pressure Sensor |
Install a manifold gauge set.
Read the manifold gauge pressure when the following conditions are met.
Prepare the vehicle according to the table below.
| Item | Condition |
|---|---|
| Vehicle Condition | Engine running |
| Doors | Fully closed (windows also fully closed) |
| A/C Switch | On |
| Recirculation/fresh Control Switch | Recirculation |
| Set Temperature | MAX COLD |
| Blower Speed | HI |
| Air Conditioning Air Inlet Temperature | 25 to 35°C (77 to 95°F) |
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
1370 to 1570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
Compare the values displayed in the Data List and on the manifold gauge.
The values displayed in the Data List and on the manifold gauge match.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
for HFO-1234yf (R1234yf):Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT (for HFO-1234yf(R1234yf))>REPLACEMENT
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
for Automatic Air Conditioning System:
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Air Mix Servo Targ Pulse(P) | No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 255 to 347 pulses for RHD:
Operates between 165 to 257 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(P) |
Damper servo motor is operated.
for Manual Air Conditioning System:
Check the operation by referring to the table below.
| Tester Display | Measurement Item | Control Range | Diagnostic Note |
|---|---|---|---|
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse | Min.: 128
Max.: 383 |
for LHD:
Operates between 165 to 257 pulses for RHD:
Operates between 255 to 347 pulses |
| Tester Display |
|---|
| Air Mix Servo Targ Pulse(D) |
Damper servo motor is operated.
| Result | Proceed to |
|---|---|
| OK (for Automatic Air Conditioning System) | A |
| OK (for Manual Air Conditioning System) | B |
| NG | C |
A
B
C
Disconnect the H1 automatic light control sensor connector.
Disconnect the G44 main body ECU (multiplex network body ECU) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| H1-1 (CLTB) - G44-23 (CLTB) | Always | Below 1 Ω |
| H1-2 (CLTE) - G44-25 (CLTE) | Always | Below 1 Ω |
| H1-4 (CLTS) - G44-24 (CLTS) | Always | Below 1 Ω |
| H1-1 (CLTB) or G44-23 (CLTB) - Other terminals and body ground | Always | 10 kΩ or higher |
| H1-2 (CLTE) or G44-25 (CLTE) - Other terminals and body ground | Always | 10 kΩ or higher |
| H1-4 (CLTS) or G44-24 (CLTS) - Other terminals and body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the automatic light control sensor.
Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC LIGHT CONTROL SENSOR>REMOVAL
Inspect the automatic light control sensor.
Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC LIGHT CONTROL SENSOR>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG