When the ultrasonic sensor is dirty or frozen, "Parking Assist Unavailable Please Clean Parking Assist Sensor" is displayed on the multi-information display in the combination meter assembly.
Clear the DTCs.
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| DTC is output | B |
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Clearance Warning / Data List
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20CB is output if YES |
| Tester Display |
|---|
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously |
| Result | Proceed to |
|---|---|
| Sensor frozen history displays "YES" | A |
| Sensor frozen history displays "NO" | B |
A
B
Clean the ultrasonic sensor from dirty or frozen.
| Proceed to |
|---|
| NEXT |
NEXT
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG) and wait 30 seconds.
Turn the GTS on.
Enter the following menus: Body Electrical / Clearance Warning / Data List
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C4 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C5 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C6 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C7 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C8 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20C9 is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20CA is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open | Open circuit status of the ultrasonic sensor | NO or YES | NO: No sensor open circuit
YES: Sensor open circuit |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt | Frozen/dirty status of the ultrasonic sensor | NO or YES | NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing | Foreign material fixing status of the ultrasonic sensor | NO or YES | NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) | Foreign material fixing (curl up) status of the ultrasonic sensor | NO or YES | NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction | Parameter malfunction status of the ultrasonic sensor | NO or YES | NO: No sensor parameter malfunction
YES: Sensor parameter malfunction |
RoB X20CB is output if YES |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously | Continuous flowing water status of the ultrasonic sensor | NO or YES | NO: No sensor continuous flowing water
YES: Sensor continuous flowing water |
RoB X20CB is output if YES |
| Tester Display |
|---|
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction |
| Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously |
| Result | Proceed to |
|---|---|
| Sensor frozen history displays "NO" | A |
| Sensor frozen history displays "YES" | B |
A
B
for Front
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR (for Front)>REMOVAL
for Rear
Click hereAudio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR (for Rear)>REMOVAL