Home › Audio / Visual / Telematics › PARK ASSIST / MONITORING › TOYOTA PARKING ASSIST-SENSOR SYSTEM (for Gasoline Model with Parking Support Brake System)
RM3620E _56 Audio / Visual / Telematics _076129 PARK ASSIST / MONITORING _0378281 TOYOTA PARKING ASSIST-SENSOR SYSTEM(for Gasoline Model with Parking Support Brake System) J

PARK ASSIST / MONITORING  TOYOTA PARKING ASSIST-SENSOR SYSTEM(for Gasoline Model with Parking Support Brake System)  Sensor Frozen Indication (Dirty or Frozen)  


DESCRIPTION

When the ultrasonic sensor is dirty or frozen, "Parking Assist Unavailable Please Clean Parking Assist Sensor" is displayed on the multi-information display in the combination meter assembly.

PROCEDURE

1.CHECK FOR DTC


Result:
Result Proceed to
DTCs are not output A
DTC is output B



A

2.READ VALUE USING GTS

B

2.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Clearance Warning / Data List


e.

According to the display on the GTS, read the Data List.

Body Electrical > Clearance Warning > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C7 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20CB is output if YES
Body Electrical > Clearance Warning > Data List
Tester Display
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously
50003 438 104,105,106,107,108,109,110,111,112,114,115,116,117,118,120,121,122,123,124,125,126,127,128,129,130,131,132,133,134,135,136,137,138,139,140,141,142,143,144,145,146,147,148,149,150,151

Result:
Result Proceed to
Sensor frozen history displays "YES" A
Sensor frozen history displays "NO" B



A

3.CLEAN ULTRASONIC SENSORS

B

4.CLEAR DTC
3.CLEAN ULTRASONIC SENSORS
a.

Clean the ultrasonic sensor from dirty or frozen.


Result:
Proceed to
NEXT



NEXT

4.CLEAR DTC
4.CLEAR DTC

Result:
Proceed to
NEXT



NEXT

5.READ VALUE USING GTS
5.READ VALUE USING GTS
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and wait 30 seconds.


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Clearance Warning / Data List


e.

According to the display on the GTS, read the Data List.

Body Electrical > Clearance Warning > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C4 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C5 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C6 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C7 is output if YES
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C7 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C8 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20C9 is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20CA is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open Open circuit status of the ultrasonic sensor NO or YES NO: No sensor open circuit
YES: Sensor open circuit
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt Frozen/dirty status of the ultrasonic sensor NO or YES NO: Sensor not frozen/dirty
YES: Sensor frozen/dirty
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing Foreign material fixing status of the ultrasonic sensor NO or YES NO: Foreign matter not stuck on sensor
YES: Foreign matter stuck on sensor
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up) Foreign material fixing (curl up) status of the ultrasonic sensor NO or YES NO: Foreign matter (curl up) not stuck on sensor
YES: Foreign matter (curl up) stuck on sensor
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction Parameter malfunction status of the ultrasonic sensor NO or YES NO: No sensor parameter malfunction
YES: Sensor parameter malfunction
RoB X20CB is output if YES
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously Continuous flowing water status of the ultrasonic sensor NO or YES NO: No sensor continuous flowing water
YES: Sensor continuous flowing water
RoB X20CB is output if YES
Body Electrical > Clearance Warning > Data List
Tester Display
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Right Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Left Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Right Corner) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Front Left Corner) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Right Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Left Center) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Right Corner) Temporarily Unavailable - Flowing Water Continuously
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Circuit Open
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Freeze/Dirt
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Foreign Material Fixing (Curl Up)
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Parameter Malfunction
Ultrasonic Sensor (Rear Left Corner) Temporarily Unavailable - Flowing Water Continuously
50003 438 104,105,106,107,108,109,110,111,112,114,115,116,117,118,120,121,122,123,124,125,126,127,128,129,130,131,132,133,134,135,136,137,138,139,140,141,142,143,144,145,146,147,148,149,150,151

Result:
Result Proceed to
Sensor frozen history displays "NO" A
Sensor frozen history displays "YES" B



A

END

B