MALFUNCTION DESCRIPTION
This DTC indicates that a large current flowed in the inverter generator. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Hybrid vehicle transaxle assembly | ·
Open or short circuit in the generator coils ·
Generator (MG1) internal malfunction (iron particles or damage from foreign objects) |
| Resolver | Open or short circuit in the generator resolver |
| Inverter | ·
Inverter internal circuit malfunction ·
Malfunction in ECU that controls the inverter ·
Inverter control sensor (current sensor, VH sensor, VL sensor) |
| Inverter cooling system | ·
Inverter water pump assembly malfunction ·
Coolant leak ·
Coolant frozen ·
Blockage |
For a description of the inverter.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A7A9E | Generator Inverter Stuck On | Generator inverter fail signal detected (circuit malfunction)
(1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Grille shutter system* ·
Wire harness or connector ·
Motor cable ·
Hybrid vehicle transaxle assembly ·
PCU fuse ·
Inverter with converter assembly ·
Hybrid vehicle control ECU assembly |
Comes on | Master Warning:
Comes on |
| P1C5F19 | Generator Inverter Circuit Current Above Threshold | Generator inverter fail signal detected:
A malfunction is detected in any of the generator components (generator inverter, generator (MG1), generator resolver, motor generator control ECU, etc.). (1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Grille shutter system* ·
Wire harness or connector ·
Motor cable ·
Hybrid vehicle transaxle assembly ·
PCU fuse ·
Inverter with converter assembly ·
Hybrid vehicle control ECU assembly |
Comes on | Master Warning:
Comes on |
*: w/ Grille Shutter
| DTC No. | Data List |
|---|---|
| P0A7A9E
P1C5F19 |
Emergency Inverter Shut Down |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY) and wait for 5 seconds or more.
Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine.
Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
Drive the vehicle approximately 10 minutes mainly using the engine.
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.
Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the Generator Resolver Circuit.
Refer to the wiring diagram for the Motor Resolver Circuit.
Refer to the wiring diagram for the Generator High-voltage Circuit.
Refer to the wiring diagram for the Motor High-voltage Circuit.
Refer to the wiring diagram for the Inverter Low-voltage Circuit.
Refer to the wiring diagram for the Cooling System.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
After troubleshooting and repairing all output DTCs, be sure to replace the inverter with converter assembly. (The inverter with converter assembly may have been broken or damaged due to overheating.)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A7A73 is not output. | A |
| P0A7A73 is also output. | B |
If P0A7A73 is output, troubleshoot it first. After completing the troubleshooting for P0A7A73, perform troubleshooting for this DTC.
Parts repaired or replaced during troubleshooting for P0A7A73 do not need to be re-inspected in this diagnostic procedure.
Turn the power switch off.
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A7A9E or P1C5F19 only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid control system in the tables below are output. | B |
| DTCs of motor generator control system in the tables below are output. | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| System Main Relay or High Voltage Circuit Malfunction | Hybrid control system | P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
| P0AD915 | Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0ADD15 | Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open | ||
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
| HV Battery Malfunction | Hybrid control system | P0AFC16 | Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold |
| P0AFC96 | Hybrid/EV Battery Sensor Module Component Internal Failure | ||
| P1CBE1E | Hybrid/EV Battery Block 1 Voltage Difference Out of Range | ||
| P1CBF1E | Hybrid/EV Battery Block 2 Voltage Difference Out of Range | ||
| P1CC01E | Hybrid/EV Battery Block 3 Voltage Difference Out of Range | ||
| P1CC11E | Hybrid/EV Battery Block 4 Voltage Difference Out of Range | ||
| P1CC21E | Hybrid/EV Battery Block 5 Voltage Difference Out of Range | ||
| P1CC31E | Hybrid/EV Battery Block 6 Voltage Difference Out of Range | ||
| P1CC41E | Hybrid/EV Battery Block 7 Voltage Difference Out of Range | ||
| P1CC51E | Hybrid/EV Battery Block 8 Voltage Difference Out of Range | ||
| P1CC61E | Hybrid/EV Battery Block 9 Voltage Difference Out of Range | ||
| P1CC71E | Hybrid/EV Battery Block 10 Voltage Difference Out of Range | ||
| P1CFD1E | Hybrid/EV Battery Block 11 Voltage Difference Out of Range | ||
| P301100 | Hybrid/EV Battery Block 1 Circuit Resistance Out of Range (Extreme) | ||
| P301200 | Hybrid/EV Battery Block 2 Circuit Resistance Out of Range (Extreme) | ||
| P301300 | Hybrid/EV Battery Block 3 Circuit Resistance Out of Range (Extreme) | ||
| P301400 | Hybrid/EV Battery Block 4 Circuit Resistance Out of Range (Extreme) | ||
| P301500 | Hybrid/EV Battery Block 5 Circuit Resistance Out of Range (Extreme) | ||
| P301600 | Hybrid/EV Battery Block 6 Circuit Resistance Out of Range (Extreme) | ||
| P301700 | Hybrid/EV Battery Block 7 Circuit Resistance Out of Range (Extreme) | ||
| P301800 | Hybrid/EV Battery Block 8 Circuit Resistance Out of Range (Extreme) | ||
| P301900 | Hybrid/EV Battery Block 9 Circuit Resistance Out of Range (Extreme) | ||
| P302000 | Hybrid/EV Battery Block 10 Circuit Resistance Out of Range (Extreme) | ||
| P302100 | Hybrid/EV Battery Block 11 Circuit Resistance Out of Range (Extreme) | ||
| U029A87 | Lost Communication with Hybrid/EV Battery Sensor Module Missing Message | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P0A1B1F | Generator Control Module Circuit Intermittent | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
| Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
| Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| Communication malfunction | Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
| Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message | |
| Sensor and actuator circuit malfunction | Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | ||
| P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
| P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | ||
| P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | ||
| P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | ||
| P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | ||
| P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | ||
| P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | ||
| P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | ||
| P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
| P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
| P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0E0012 | Generator Phase U Current Sensor Circuit Short to Battery | ||
| P0E0014 | Generator Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0E0028 | Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0412 | Generator Phase V Current Sensor Circuit Short to Battery | ||
| P0E0414 | Generator Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0E0428 | Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E0812 | Generator Phase W Current Sensor Circuit Short to Battery | ||
| P0E0814 | Generator Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0E0828 | Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
| P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | ||
| P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
| P0E5128 | DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | ||
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| P1CFF62 | Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure | ||
| Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | ||
| System malfunction | Motor generator control system | P0A9000 | Drive Motor "A" Performance |
| P0A9200 | Hybrid Generator Performance | ||
| P0A949E | DC/DC Converter Stuck On | ||
| P0CA300 | DC/DC Converter Step Up Voltage Performance | ||
| P0D3319 | DC/DC Converter Circuit Current Above Threshold | ||
| P0E5717 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E7100 | Generator Execution Torque Performance | ||
| P1CA51D | Hybrid Generator Circuit Current Out of Range | ||
| P1CB59E | DC/DC Converter Voltage Sensor "A" (VL) Stuck On | ||
| P314F1F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent | ||
| P31531D | DC/DC Converter Current Sensor Circuit Current Out of Range | ||
| Hybrid control system | P0A9300 | Inverter "A" Cooling System Performance | |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure | ||
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure | ||
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | ||
| Relevant DTC | |
|---|---|
| P0A3F1F | Drive Motor "A" Position Sensor Circuit Intermittent |
| P0A4B1F | Generator Position Sensor Circuit Intermittent |
| P0A601F | Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent |
| P0A631F | Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent |
| P0BE51F | Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
| P0BE91F | Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
| P0BED1F | Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
| P0C501F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5A1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
| P0C641F | Generator Position Sensor Circuit "A" Circuit Intermittent |
| P0C691F | Generator Position Sensor Circuit "B" Circuit Intermittent |
| P0D2D1F | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent |
| P0E001F | Generator Phase U Current Sensor Circuit Intermittent |
| P0E041F | Generator Phase V Current Sensor Circuit Intermittent |
| P0E081F | Generator Phase W Current Sensor Circuit Intermittent |
| P0E311F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
| P0E511F | DC/DC Converter Current Sensor Circuit Intermittent |
| P1C601F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
| P1C621F | Generator Control Module Offset Power Circuit Intermittent |
| P1C641F | Generator Control Module Circuit Intermittent |
| P1C651F | Generator Control Module Circuit Intermittent |
| P1C671F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
| P1C691F | Generator Phase U-V-W Current Sensor Circuit Intermittent |
| P31241F | Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
P0A7A9E or P1C5F19 may be output as a result of the malfunctions indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
If DTC P0A7A9E is output, replace the inverter with converter assembly after completing repairs.
Turn the power switch off.
A
B
C
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.
| Tester Display |
|---|
| Diagnosis Related Information |
Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Read the diagnosis related information and freeze frame data of DTC P0A7A9E or P1C5F19.
| Result | Proceed to |
|---|---|
| DTC P312487 is listed in Diagnosis Related Information. | A |
| DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. | B |
| Other than above | C |
Turn the power switch off.
A
B
C
After repairs have been completed, perform the next step.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A7A9E or P1C5F19 only is output, or DTCs except the ones in the table below are also output. | A |
| DTCs of hybrid control system in the tables below are output. | B |
| DTCs of motor generator control system in the tables below are output. | C |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Motor generator control system | P0A1A47 | Generator Control Module Watchdog / Safety MC Failure |
| P0A1A49 | Generator Control Module Internal Electronic Failure | ||
| P0A1B1F | Generator Control Module Circuit Intermittent | ||
| P1C2A1C | Generator A/D Converter Circuit Circuit Voltage Out of Range | ||
| P1C2A49 | Generator A/D Converter Circuit Internal Electronic Failure | ||
| P1C2B1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range | ||
| P1C2B49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure | ||
| P313383 | Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect | ||
| P313386 | Communication Error from Generator to Drive Motor "A" Signal Invalid | ||
| P313387 | Communication Error from Generator to Drive Motor "A" Missing Message | ||
| P313483 | Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect | ||
| P313486 | Communication Error from Drive Motor "A" to Generator Signal Invalid | ||
| P313487 | Communication Error from Drive Motor "A" to Generator Missing Message | ||
| Hybrid control system | P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | |
| Power source circuit malfunction | Motor generator control system | P06B01C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range | ||
| Communication malfunction | Motor generator control system | P312487 | Lost Communication between Drive Motor "A" and HV ECU Missing Message |
| Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message | |
| Sensor and actuator circuit malfunction | Motor generator control system | P0A3F16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum | ||
| P0A3F22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum | ||
| P0A4B16 | Generator Position Sensor Circuit Voltage Below Threshold | ||
| P0A4B21 | Generator Position Sensor Signal Amplitude < Minimum | ||
| P0A4B22 | Generator Position Sensor Signal Amplitude > Maximum | ||
| P0A6012 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery | ||
| P0A6014 | Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A601C | Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range | ||
| P0A6312 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery | ||
| P0A6314 | Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open | ||
| P0A631C | Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range | ||
| P0BE512 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery | ||
| P0BE514 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open | ||
| P0BE528 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BE912 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery | ||
| P0BE914 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open | ||
| P0BE928 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BED12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery | ||
| P0BED14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open | ||
| P0BED28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | ||
| P0BFD62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0C5013 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open | ||
| P0C5016 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C5017 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C5A13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open | ||
| P0C5A16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C5A17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0C6413 | Generator Position Sensor Circuit "A" Circuit Open | ||
| P0C6416 | Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold | ||
| P0C6417 | Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold | ||
| P0C6913 | Generator Position Sensor Circuit "B" Circuit Open | ||
| P0C6916 | Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold | ||
| P0C6917 | Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold | ||
| P0D2D16 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold | ||
| P0D2D17 | Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold | ||
| P0DFA62 | Generator Phase U-V-W Current Sensor Signal Compare Failure | ||
| P0E3116 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold | ||
| P0E3117 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E5111 | DC/DC Converter Current Sensor Circuit Short to Ground | ||
| P0E5115 | DC/DC Converter Current Sensor Circuit Short to Battery or Open | ||
| P0E512A | DC/DC Converter Current Sensor Signal Stuck In Range | ||
| P1CAC49 | Generator Position Sensor Internal Electronic Failure | ||
| P1CAD49 | Drive Motor "A" Position Sensor Internal Electronic Failure | ||
| P1CAF38 | Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect | ||
| P1CB038 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect | ||
| Hybrid control system | P0C7600 | Hybrid/EV Battery System Discharge Time Too Long | |
| P0D2D1C | Drive Motor "A" Inverter Voltage Sensor Voltage Out of Range | ||
| P0E311C | Boosting Converter Voltage Sensor "A" Voltage Out of Range | ||
| System malfunction | Motor generator control system | P0A9000 | Drive Motor "A" Performance |
| P0A949E | DC/DC Converter Stuck On | ||
| P0CA300 | DC/DC Converter Step Up Voltage Performance | ||
| P0D3319 | DC/DC Converter Circuit Current Above Threshold | ||
| P0E5717 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold | ||
| P0E7100 | Generator Execution Torque Performance | ||
| P1CA51D | Hybrid Generator Circuit Current Out of Range | ||
| P1CB59E | DC/DC Converter Voltage Sensor "A" (VL) Stuck On | ||
| P314F1F | DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent | ||
| P31531D | DC/DC Converter Current Sensor Circuit Current Out of Range | ||
| Hybrid control system | P0A9300 | Inverter "A" Cooling System Performance | |
| P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure | ||
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure | ||
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | ||
P0A7A9E or P1C5F19 may be output as a result of the malfunctions indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
If DTC P0A7A9E is output, replace the inverter with converter assembly after completing repairs.
Turn the power switch off.
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
| Proceed to |
|---|
| NEXT |
NEXT