MALFUNCTION DESCRIPTION
This DTC indicates that a large current flowed through the rear motor inverter. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Rear traction motor with transaxle assembly | ·
Open or short circuit in the rear motor coils ·
Rear motor (MGR) internal malfunction (iron particles or damage from foreign objects) |
| Resolver | Open or short circuit in the rear motor resolver |
| Rear motor inverter | ·
Rear motor inverter internal circuit malfunction ·
Malfunction in ECU that controls the rear motor inverter ·
Rear motor inverter control sensor (current sensor, voltage sensors (VH, VL), etc.) |
| Inverter cooling system | ·
Inverter water pump assembly malfunction ·
Coolant leak ·
Frozen ·
Blockage |
For a description of the inverter.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
| P0A799E | Drive Motor "B" Inverter Stuck On | Rear motor inverter fail signal detected (circuit malfunction)
(1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Grille shutter system* ·
Wire harness or connector ·
HV floor under wire (rear traction motor cable) ·
Motor cable ·
Hybrid vehicle transaxle assembly ·
Rear traction motor with transaxle assembly ·
PCU fuse ·
Inverter with converter assembly ·
Hybrid vehicle control ECU assembly |
Comes on | Master Warning:
Comes on |
| P1C5E19 | Drive Motor "B" Inverter Circuit Current Above Threshold | Rear motor inverter fail signal detected:
A malfunction is detected in any of the rear motor components (rear motor inverter, rear motor, motor generator control ECU, etc.) (1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Grille shutter system* ·
Wire harness or connector ·
HV floor under wire (rear traction motor cable) ·
Motor cable ·
Hybrid vehicle transaxle assembly ·
Rear traction motor with transaxle assembly ·
PCU fuse ·
Inverter with converter assembly ·
Hybrid vehicle control ECU assembly |
Comes on | Master Warning:
Comes on |
*: w/ Grille Shutter
| DTC No. | Data List |
|---|---|
| P0A799E
P1C5E19 |
Emergency Shutdown Signal |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Connect the GTS to the DLC3.
Turn the power switch on (IG) and turn the GTS on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the power switch off and wait for 2 minutes or more.
Turn the power switch on (IG) and turn the GTS on.
With power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY) and wait for 5 seconds or more.
Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
With the vehicle stopped, begin moving with the accelerator opening angle between 20% to 50% and a speed of approximately 10 km/h (6 mph), then stop the vehicle and repeat the same procedure several times.
While doing this, check that the "Rear Motor Torque" value does not remain at 0 N*m continuously, but rather changes to indicate that the rear motor is operating.
(Unless rear motor torque is restricted due to DTC output, the rear motor torque will not remain at 0 N*m continuously.)
Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Refer to the wiring diagram for the Generator Resolver Circuit.
Refer to the wiring diagram for the Motor Resolver Circuit.
Refer to the wiring diagram for the Rear Motor Resolver Circuit.
Refer to the wiring diagram for the Generator High-voltage Circuit.
Refer to the wiring diagram for the Motor High-voltage Circuit.
Refer to the wiring diagram for the Rear Motor High-voltage Circuit.
Refer to the wiring diagram for the Inverter Low-voltage Circuit.
Refer to the wiring diagram for the Cooling System.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
After troubleshooting and repairing all output DTCs, be sure to replace the inverter with converter assembly. (The inverter with converter assembly may have been broken or damaged due to overheating.)
Go to Motor Generator Control System.
For the P0A799E and P1C5E19 inspection procedures, refer to the Motor Generator Control System section.
| Result |
|---|
| NEXT |
NEXT