Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › REAR MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY) › from 2019.02
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0390718 REAR MOTOR GENERATOR CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY) C

HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM(for NICKEL METAL HYDRIDE BATTERY)  P0C021D  Drive Motor "B" System Circuit Current Out of Range  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC is stored when the rear motor control system is malfunctioning and current does not flow as commanded. The cause of this malfunction may be one of the following:

Area Main Malfunction Description
Inside of inverter Inverter with converter assembly internal circuit malfunction
Rear traction motor with transaxle assembly
·

Rear motor (MGR) internal malfunction (entry of foreign matter, etc.)

·

Open or short circuit in the rear motor coils


Inverter low-voltage circuit The connectors are not connected properly
HV floor under wire (rear traction motor cable)
·

Defective HV floor under wire (rear traction motor cable) connection

·

Open circuit or poor insulation on HV floor under wire (rear traction motor cable)


Hybrid vehicle control ECU assembly Hybrid vehicle control ECU assembly internal circuit malfunction


DESCRIPTION

For a description of the inverter.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>P0D2D16

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0C021D Drive Motor "B" System Circuit Current Out of Range Rear motor system malfunction:
If current does not flow as commanded, the rear motor high voltage system may be malfunctioning.
Malfunction is detected when the vehicle is stopped or being driven at low speeds.
(1 trip detection logic)
·

Hybrid vehicle transaxle assembly

·

Rear traction motor with transaxle assembly

·

HV floor under wire (rear traction motor cable)

·

Motor cable

·

Inverter with converter assembly

·

Wire harness or connector

·

Hybrid vehicle control ECU assembly


Comes on Master Warning:
Comes on

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

Start the vehicle from a stop and drive the vehicle until the vehicle speed reaches approximately 10 km/h (6 mph). Repeat this procedure a few times.

7.

Enter the following menus: Powertrain / Rear Motor Generator / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358


·

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C05
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR MOTOR GENERATOR CONTROL SYSTEM (for NICKEL METAL HYDRIDE BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.




NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


HINT:

If an abnormality occurs after disconnecting and connecting the motor cable and HV floor under wire (rear traction motor cable), reconfirm the cable connection condition.


PROCEDURE

1.GO TO MOTOR GENERATOR CONTROL SYSTEM
a.

Go to Motor Generator Control System.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM (for 4WD/AWD with NICKEL METAL HYDRIDE BATTERY)>P0C021D

HINT:

For the P0C021D inspection procedures, refer to the Motor Generator Control System section.



Result:
Result
NEXT



NEXT

END