Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY) › from 2020.05
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0425055 HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY) C

HYBRID / BATTERY CONTROL  HYBRID BATTERY SYSTEM(for LITHIUM-ION BATTERY)  P0AAC11  Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground  P0AAC15  Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open  


DESCRIPTION

The inlet air temperature sensor (battery) is mounted on the HV battery. The resistance of the sensor varies in accordance with changes in the intake air temperature. The characteristics of the inlet air temperature sensor are the same as those of the battery temperature sensors (Click here Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>P0A9B11). The battery ECU assembly uses signals from the inlet air temperature sensor to control the air volume of the battery cooling blower assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate
P0AAC11 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Ground The inlet air temperature sensor output voltage is lower than the specified value (short circuit) and the detected temperature is higher than the specified value.
(1 trip detection logic)
·

No. 1 HV supply stack sub-assembly

·

Battery ECU assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on
P0AAC15 Hybrid/EV Battery Air Temperature Sensor "A" Circuit Short to Auxiliary Battery or Open The inlet air temperature sensor output voltage is higher than the standard value (short to +B or open) and the detected temperature is lower than the specified value.
(1 trip detection logic)
·

No. 1 HV supply stack sub-assembly

·

Battery ECU assembly

·

Wire harness or connector


Does not come on Master Warning:
Comes on

HINT:

After checking for the above DTCs, check the hybrid system Data List item "Hybrid/EV Battery Cooling Fan Intake Air Temperature 1" using the GTS.

Displayed Temperature Malfunction
-45°C (-49°F) or less Open or +B short circuit
95°C (203°F) or more GND short


Related Data List
DTC No. Data List
P0AAC11 Hybrid/EV Battery Cooling Fan Intake Air Temperature 1
P0AAC15

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>UTILITY


1.

Connect the GTS to the DLC3.

2.

Turn the power switch on (IG) and turn the GTS on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

4.

Turn the power switch off and wait for 2 minutes or more.

5.

Turn the power switch on (IG) and turn the GTS on.

6.

With power switch on (IG) and wait for 5 seconds.

7.

Enter the following menus: Powertrain / HV Battery / Utility / All Readiness.

8.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




WIRING DIAGRAM

A409010E06
3.156,1.073 3.615,1.271 0.458,0.198 10 false VIB 1.583,0.719 3.26,1.01 1.677,0.292 10 false Battery Current Sensor 3.49,1.073 3.948,1.406 0.458,0.333 10 false 1 3.167,1.438 3.625,1.635 0.458,0.198 10 false IB0 3.49,1.438 3.948,1.771 0.458,0.333 10 false 4 3.177,1.813 3.635,2.219 0.458,0.406 10 false IB1 3.49,1.813 3.948,2.146 0.458,0.333 10 false 2 3.156,2.156 3.615,2.563 0.458,0.406 10 false GIB 3.5,2.146 3.958,2.479 0.458,0.333 10 false 3 0.615,2.635 3.25,3.094 2.635,0.458 10 false z25 HV Battery junction Block Assembly 5.302,1.073 5.76,1.271 0.458,0.198 10 false VIB 5.302,1.438 5.76,1.635 0.458,0.198 10 false IB0 5.302,1.823 5.76,2.229 0.458,0.406 10 false IB1 5.302,2.146 5.76,2.552 0.458,0.406 10 false GIB 5.042,1.083 5.5,1.417 0.458,0.333 10 false 36 5.042,1.427 5.5,1.76 0.458,0.333 10 false 12 5.052,1.813 5.51,2.146 0.458,0.333 10 false 24 5.052,2.135 5.51,2.469 0.458,0.333 10 false 23 5,5.448 6.875,5.75 1.875,0.302 10 false z26 Battery ECU Assembly 1.615,3.365 3.823,3.677 2.208,0.313 10 false Inlet Air Temperature Sensor 0.917,4.104 3.813,4.479 2.896,0.375 10 false No. 2 HV Supply Stack Sub-assembly 0.948,5.25 4.021,5.656 3.073,0.406 10 false No. 1 HV Supply Stack Sub-assembly 5.281,3.083 5.74,3.49 0.458,0.406 10 false TC0 5.281,3.49 5.74,3.896 0.458,0.406 10 false GC0 5.042,3.083 5.5,3.49 0.458,0.406 10 false 22 5.052,3.51 5.51,3.917 0.458,0.406 10 false 21 3.958,3.969 4.417,4.375 0.458,0.406 10 false A 3.792,1.073 4.25,1.406 0.458,0.333 10 false 1 4.167,1.073 4.625,1.406 0.458,0.333 10 false 1 3.74,1.448 4.198,1.781 0.458,0.333 10 false 11 4.135,1.448 4.594,1.781 0.458,0.333 10 false 11 3.781,1.823 4.24,2.156 0.458,0.333 10 false 2 4.167,1.823 4.625,2.156 0.458,0.333 10 false 2 3.708,2.156 4.167,2.49 0.458,0.333 10 false 10 4.146,2.156 4.604,2.49 0.458,0.333 10 false 10 4.146,3.5 4.604,3.833 0.458,0.333 10 false 3 3.781,3.5 4.24,3.833 0.458,0.333 10 false 3 3.719,3.083 4.177,3.417 0.458,0.333 10 false 12 4.146,3.083 4.604,3.417 0.458,0.333 10 false 12

CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the HV battery


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C02
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM (for LITHIUM-ION BATTERY)>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.

If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358021C02
0.531,4.146 0.844,4.344 0.313,0.198 10 false *a 2.74,4.146 3.052,4.344 0.313,0.198 10 false *b
*a Dealer
*b Battery Collection Agent


When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

-

Accidents such as electric shock may result if the HV battery is disposed of improperly or abandoned. Therefore, make sure to return all HV batteries through an authorized collection agent.


·

Before returning the HV battery, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Before returning the HV supply stack sub-assembly, make sure to perform a recovery inspection.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY STACK (for LITHIUM-ION BATTERY)>RECOVERY INSPECTION

·

Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery and HV supply stack sub-assemblies.

·
A358020

After removing the HV battery, keep it away from water. Exposure to water may cause the HV battery to produce heat, resulting in a fire.



NOTICE:

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

1.CHECK DTC OUTPUT (HV BATTERY, HYBRID CONTROL)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Enter the following menus: Powertrain / HV Battery and Hybrid Control / Trouble Codes.


d.

Check for DTCs.

Powertrain > HV Battery > Trouble Codes
50001 398
Powertrain > Hybrid Control > Trouble Codes
50001 397
Result:
Result Proceed to
"P0AAC11 or P0AAC15" only is output, or DTCs except the ones in the table below are also output. A
DTCs of hybrid battery system in the table below are output. B
DTCs of hybrid control system in the table below are output. C


System Relevant DTC
Hybrid battery system P060A47 Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure
P060B49 Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure
P060687 Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message
Hybrid control system P0A1F94 Hybrid/EV Battery Energy Control Module Unexpected Operation


e.

Turn the power switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INLET AIR TEMPERATURE SENSOR)

B

C

2.CHECK CONNECTOR CONNECTION CONDITION (INLET AIR TEMPERATURE SENSOR)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
C433532N01
2.188,0.823 2.604,1.073 0.417,0.25 2.271,0.854 2.563,1.052 0.292,0.198 10 true z26

Check the connections of the z26 battery ECU assembly connector.

Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>ELECTRONIC CIRCUIT INSPECTION PROCEDURE

OK:

The connector is connected securely and there are no contact problems.


Result:
Proceed to
OK
NG



d.

Install the No. 1 HV battery hose.



OK

3.CHECK INSTALLATION OF INLET AIR TEMPERATURE SENSOR

NG

CONNECT SECURELY

3.CHECK INSTALLATION OF INLET AIR TEMPERATURE SENSOR
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

c.
C433543

Visually check the installation condition of the inlet air temperature sensor.

Result:
Result Proceed to
The inlet air temperature sensor is installed in the correct location and its claws are engaged securely. A
The claws of the inlet air temperature sensor are damaged. B
The inlet air temperature sensor is not installed correctly, but its claws are not damaged. C



d.

Install the upper HV battery cover sub-assembly.



A

4.CHECK HV BATTERY (INLET AIR TEMPERATURE SENSOR)

B

C

INSTALL PARTS CORRECTLY

4.CHECK HV BATTERY (INLET AIR TEMPERATURE SENSOR)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
C433532N01
2.188,0.823 2.604,1.073 0.417,0.25 2.271,0.854 2.563,1.052 0.292,0.198 10 true z26

Disconnect the z26 battery ECU assembly connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



d.
A407388C36
1.49,0.396 1.938,0.635 0.448,0.24 2.083,2.271 2.906,0.99 true 1.958,2.271 2.729,0.802 true 0.146,0.115 0.604,0.531 0.458,0.417 10 false *a 1.594,0.427 2.052,0.844 0.458,0.417 10 false z26 2.938,0.917 3.354,1.198 0.417,0.281 10 false TC0 2.771,0.719 3.188,0.958 0.417,0.24 10 false GC0
*a Front view of wire harness connector
(to Battery ECU Assembly)


Measure the resistance according to the value (s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z26-22 (TC0) - z26-21 (GC0) Power switch off
0 to 10°C (32 to 50°F)
17.7 to 27.8 kΩ
z26-22 (TC0) - z26-21 (GC0) Power switch off
10 to 20°C (50 to 68°F)
12.0 to 18.2 kΩ
z26-22 (TC0) - z26-21 (GC0) Power switch off
20 to 30°C (68 to 86°F)
8.22 to 12.2 kΩ
z26-22 (TC0) - z26-21 (GC0) Power switch off
30 to 40°C (86 to 104°F)
5.74 to 8.41 kΩ
z26-22 (TC0) - z26-21 (GC0) Power switch off
40 to 50°C (104 to 122°F)
4.09 to 5.91 kΩ


NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



e.

Measure the resistance according to the value (s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
z26-22 (TC0) - Body ground and other terminals Power switch off 10 kΩ or higher
z26-21 (GC0) - Body ground and other terminals Power switch off 10 kΩ or higher



f.

Connect the cable to the negative (-) auxiliary battery terminal.


g.

Turn the power switch on (IG).


h.

Measure the voltage according to the value (s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
z26-22 (TC0) - Body ground Power switch on (IG) Below 1 V
z26-21 (GC0) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.



i.

Turn the power switch off.


j.

Disconnect the cable from the negative (-) auxiliary battery terminal.


k.

Reconnect the z26 battery ECU assembly connectors.


l.

Install the No. 1 HV battery hose.


Result:
Proceed to
OK
NG



OK

5.CHECK BATTERY ECU ASSEMBLY (VIB VOLTAGE)

NG

9.CHECK HV BATTERY (INLET AIR TEMPERATURE SENSOR)
5.CHECK BATTERY ECU ASSEMBLY (VIB VOLTAGE)

OK

NG

6.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE)
6.CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (BATTERY CURRENT SENSOR OUTPUT VOLTAGE)

OK

NG

7.CHECK HARNESS AND CONNECTOR (NO. 2 HV SUPPLY STACK SUB-ASSEMBLY - HV BATTERY JUNCTION BLOCK ASSEMBLY)
7.CHECK HARNESS AND CONNECTOR (NO. 2 HV SUPPLY STACK SUB-ASSEMBLY - HV BATTERY JUNCTION BLOCK ASSEMBLY)

OK

8.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 1 HV SUPPLY STACK SUB-ASSEMBLY)

NG

8.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - NO. 1 HV SUPPLY STACK SUB-ASSEMBLY)

OK

NG

9.CHECK HV BATTERY (INLET AIR TEMPERATURE SENSOR)
CAUTION:

Be sure to wear insulated gloves and protective goggles.


a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.




c.
C433539N01
2.01,0.948 2.406,1.198 0.396,0.25 2.094,0.979 2.323,1.156 0.229,0.177 10 true A

Disconnect the A No. 2 HV supply stack sub-assembly connector.

NOTICE:

Before disconnecting the connector, check that it is not loose or disconnected.



d.
A406240C03
1.521,0.094 1.906,0.375 0.385,0.281 0.729,1.729 1.375,1.406 true 1.375,1.021 0.646,0.708 true 0.125,0.104 0.479,0.396 0.354,0.292 10 false *a 1.656,0.146 2.01,0.438 0.354,0.292 10 false A 0.448,1.698 0.802,1.99 0.354,0.292 10 false TC0 0.354,0.646 0.708,0.938 0.354,0.292 10 false GC0
*a Front view of wire harness connector
(to No. 1 HV Supply Stack Sub-assembly)


Measure the resistance according to the value (s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-12 (TC0) - A-3 (GC0) Power switch off
0 to 10°C (32 to 50°F)
17.7 to 27.8 kΩ
A-12 (TC0) - A-3 (GC0) Power switch off
10 to 20°C (50 to 68°F)
12.0 to 18.2 kΩ
A-12 (TC0) - A-3 (GC0) Power switch off
20 to 30°C (68 to 86°F)
8.22 to 12.2 kΩ
A-12 (TC0) - A-3 (GC0) Power switch off
30 to 40°C (86 to 104°F)
5.74 to 8.41 kΩ
A-12 (TC0) - A-3 (GC0) Power switch off
40 to 50°C (104 to 122°F)
4.09 to 5.91 kΩ


NOTICE:

When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.



e.

Measure the resistance according to the value (s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A-12 (TC0) - Body ground and other terminals Power switch off 10 kΩ or higher
A-3 (GC0) - Body ground and other terminals Power switch off 10 kΩ or higher



f.

Connect the cable to the negative (-) auxiliary battery terminal.


g.

Turn the power switch on (IG).


h.

Measure the voltage according to the value (s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A-12 (TC0) - Body ground Power switch on (IG) Below 1 V
A-3 (GC0) - Body ground Power switch on (IG) Below 1 V


NOTICE:

Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.



i.

Turn the power switch off.


j.

Disconnect the cable from the negative (-) auxiliary battery terminal.


k.

Reconnect the A No. 2 HV supply stack sub-assembly connector.


l.

Install the No. 1 HV battery hose.


Result:
Proceed to
OK
NG



OK

NG