Home › Engine / Hybrid System ยท 3UR-FBE › ENGINE CONTROL › SFI SYSTEM

DTC    P0116    Engine Coolant Temperature Circuit Range / Performance Problem

for Preparation Click here


DESCRIPTION

Refer to DTC P0115 .

DTC No.
DTC Detection Condition
Trouble Area
P0116
When either of following conditions met (2 trip detection logic):
  1. When cold engine started and engine warmed up, Engine Coolant Temperature (ECT) sensor value does not change.
  2. After warmed up engine stopped and then next cold engine start performed, ECT sensor value does not change.
  1. Thermostat
  2. ECT sensor

MONITOR DESCRIPTION

  1. Engine coolant temperature (ECT) sensor cold start monitor
    When a cold engine start is performed and then the engine is warmed up, if the ECT sensor value does not change, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.
  1. ECT sensor soak monitor
    If the ECT sensor value does not change after the warmed up engine is stopped and then the next cold engine start is performed, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.

MONITOR STRATEGY


Related DTCs
P0116: Engine coolant temperature (ECT) sensor cold start monitor
P0116: ECT sensor soak monitor
Required Sensors/Components (Main)
ECT sensor
Required Sensors/Components (Related)
None
Frequency of Operation
Once per driving cycle
Duration
10 seconds or more
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


ECT Sensor Cold Start Monitor 
Monitor runs whenever following DTCs not present
P0112, P0113 (Intake Air Temperature Sensor)
Battery voltage
10.5 V or more
Time after engine start
1 second or more
ECT at engine start
Less than 60°C (140°F)
Soak time
0 seconds or more
Accumulated MAF
1963 g or more
Fuel cut
OFF
Difference between ECT at engine start and IAT
Less than 40°C (72°F)

ECT Sensor Soak Monitor 
Monitor runs whenever following DTCs not present
P0112, P0113 (Intake Air Temperature Sensor)
Battery voltage
10.5 V or more
Engine
Running
Soak time
5 hours or more
Either (a) or (b) condition met
-
(a) ECT
60°C (140°F) or more
(b) Accumulated MAF
3931 g or more

TYPICAL MALFUNCTION THRESHOLDS


ECT Sensor Cold Start Monitor 
ECT sensor value change
Less than 5°C (9°F)

ECT Sensor Soak Monitor 
Difference between current ECT sensor value and previous ECT sensor value when engine stopped
Less than 5°C (9°F) [varies with ECT of last trip engine stop]

COMPONENT OPERATING RANGE


ECT
ECT sensor value changes in accordance with actual ECT

INSPECTION PROCEDURE

HINT:
  1. If any of DTCs P0115, P0117, P0118 or P0125 are stored simultaneously with DTC P0116, the ECT sensor may have an open or a short circuit. Troubleshoot those DTCs first.
  2. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.

  1. Read the DTC.
    Result 
    Result
    Proceed to
    P0116 is output
    A
    P0116 and other DTCs are output
    B



B
GO TO DTC CHART (Click here)
A


2.INSPECT THERMOSTAT
  1. Remove the thermostat (Click here).

  1. Measure the valve opening temperature of the thermostat.

    Standard opening temperature:
    80 to 84°C (176 to 183°F)

    HINT:
    In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

  1. Reinstall the thermostat (Click here).



NG
REPLACE THERMOSTAT (Click here)
OK

REPLACE ENGINE COOLANT TEMPERATURE SENSOR (Click here)