Home › Engine / Hybrid System ยท 2UZ-FE › ENGINE CONTROL › SFI SYSTEM

DTC    P0128    Coolant Thermostat (Coolant Temperature Below Thermostat Regulating Temperature)

for Preparation Click here


DESCRIPTION

This DTC is stored when the Engine Coolant Temperature (ECT) does not reach 75°C (167°F) despite sufficient engine warm-up time having elapsed.

DTC No.
DTC Detection Condition
Trouble Area
P0128
  1. Conditions (a), (b) and (c) met for 5 seconds (2 trip detection logic):
  2. (a) Cold start
  3. (b) Engine warmed up
  4. (c) ECT less than 75°C (167°F)
  1. Thermostat
  2. Cooling system
  3. ECT sensor
  4. ECM

MONITOR DESCRIPTION


A121605E02

The ECM estimates the ECT based on the starting temperature, engine loads, and engine speeds. The ECM then compares the estimated temperature with the actual ECT. When the estimated ECT reaches 75°C (167°F), the ECM checks the actual ECT. If the actual ECT is less than 75°C (167°F), the ECM interprets this as a malfunction in the thermostat or the engine cooling system and stores the DTC.

MONITOR STRATEGY


Related DTCs
P0128: Coolant Thermostat
Required Sensors/Components (Main)
Thermostat
Required Sensors/Components (Related)
Engine Coolant Temperature (ECT) sensor, Intake Air Temperature (IAT) sensor, Vehicle speed sensor
Frequency of Operation
Once per driving cycle
Duration
900 seconds
MIL Operation
2 driving cycles
Sequence of Operation
None

TYPICAL ENABLING CONDITIONS


Monitor runs whenever following DTCs not present
P0010, P0020 (VVT Oil Control Valve)
P0011, P0021 (VVT System - Advance)
P0012, P0022 (VVT System - Retard)
P0016, P0018 (VVT System - Misalignment)
P0031, P0032, P0051, P0052 (Air Fuel Ratio Sensor Heater)
P2195, P2196, P2197, P2198, P2237, P2238, P2239, P2240, P2241, P2242, P2252, P2253, P2255, P2256, P2A00, P2A03 (Air Fuel Ratio Sensor)
P0102, P0103 (Mass Air Flow Sensor)
P0110, P0112, P0113 (Intake Air Temperature Sensor)
P0115, P0117, P0118 (Engine Coolant Temperature Sensor)
P0120, P0121, P0122, P0123, P0220, P0222, P0223, P2135 (Throttle Position Sensor)
P0171, P0172, P0174, P0175 (Fuel System)
P0300 - P0308 (Misfire)
P0335 (Crankshaft Position Sensor)
P1340 (Camshaft Position Sensor)
P0340, P0345 (VVT Sensor)
P0351 - P0358 (Igniter)
P0500 (Vehicle Speed Sensor)
Battery voltage
11 V or more
Either of following conditions 1 or 2 met:
-
1. All of following conditions met:
-
  1. ECT at engine start - IAT at engine start
-15 to 7°C (-27 to 12.6°F)
  1. ECT at engine start
-10 to 56°C (14 to 133°F)
  1. IAT at engine start
-10 to 56°C (14 to 133°F)
2. All of following conditions met:
-
  1. ECT at engine start - IAT at engine start
More than 7°C (12.6°F)
  1. ECT at engine start
56°C (133°F) or less
  1. IAT at engine start
-10°C (14°F) or more
Accumulated time at 128 km/h (80 mph) or more of vehicle speed
Less than 20 seconds

TYPICAL MALFUNCTION THRESHOLDS


Duration that both of following conditions (a) and (b) met
5 seconds or more
(a) Estimated ECT
75°C (167°F) or more
(b) ECT sensor output
Below 75°C (167°F)

INSPECTION PROCEDURE

HINT:
  1. This DTC relates to the thermostat.
  2. Read freeze frame data using the Techstream. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0128)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream ON.

  1. Enter the following menus: Powertrain / Engine / Trouble Codes.

  1. Read DTCs.
    Result 
    Result
    Proceed to
    P0128 is output
    A
    P0128 and other DTCs are output
    B

    HINT:
    If any DTCs other than P0128 are output, troubleshoot those DTCs first.



B
GO TO DTC CHART (Click here)
A


2.CHECK COOLING SYSTEM
  1. Check for defects in the cooling system that might cause the system to be too cold, such as abnormal radiator fan operation or any modifications.



NG
REPAIR OR REPLACE COOLING SYSTEM
OK


3.INSPECT THERMOSTAT
  1. Remove the thermostat (Click here).

  1. Measure the valve opening temperature of the thermostat.

    Standard:
    80 to 84°C (176 to 183°F)

    HINT:
    In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

  1. Reinstall the thermostat (Click here).



NG
REPLACE THERMOSTAT (Click here)
OK

REPLACE ECM (Click here)