DTC P0778 Pressure Control Solenoid "B" Electrical (Shift Solenoid Valve SL2) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P0778 |
|
|
| Related DTCs | P0778: Shift solenoid valve SL2/Range check |
| Required sensors/Components | Shift solenoid valve SL2 |
| Frequency of operation | Continuous |
| Duration | 1 second |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Ignition switch | ON |
| Starter | OFF |
| Battery voltage | 8 V or more |
| Battery voltage | 10 V or more and less than 12 V |
| CPU commanded duty | Less than 75% |
| Output signal duty | 100% |
| Output signal duty | More than 3% and less than 100% |

| ECM gear shift command | 1st | 2nd | 3rd | 4th | 5th |
| Shift solenoid valve SL2 | ON | ON | ON | ON | OFF |
| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL2) |
![]() |
Disconnect the D41 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 11 (SL2+) - 3 (SL2-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 11 (SL2+) - Body ground | Always | 10 kΩ or higher |
| 3 (SL2-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D56 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D56-12 (SL2+) - D56-13 (SL2-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D56-12 (SL2+) - Body ground | Always | 10 kΩ or higher |
| D56-13 (SL2-) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SL2 |
![]() |
Remove the shift solenoid valve SL2.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the battery positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
|
| ||||
| OK | ||
| ||