INTUITIVE PARKING ASSIST SYSTEM > Back Sonar Sensor LH Circuit |

| 1.REPLACE BACK NO. 2 ULTRASONIC SENSOR LH |
Replace the back No. 2 ultrasonic sensor with a normally functioning sensor (Click here).
| NEXT | |
| 2.CHECK HARNESS AND CONNECTOR (BACK SENSOR LH - BACK SENSOR RH) |
![]() |
Disconnect the R4 and R3 back No. 2 ultrasonic sensor connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Condition | Condition | Specified Condition |
| R4-1 (BI) - R3-2 (BO) | Always | Below 1 Ω |
| R4-3 (SI) - R3-4 (SO) | ||
| R4-5 (EI) - R3-6 (EO) | ||
| R4-1 (BI) - Body ground | Always | 10 kΩ or higher |
| R4-3 (SI) - Body ground | ||
| R4-5 (EI) - Body ground |
Reconnect the back No. 2 ultrasonic sensor connectors.
|
| ||||
| OK | ||
| ||