DTC    B1411/11    Room Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The cooler thermistor (front room temperature sensor) is installed in the instrument panel to detect the room temperature and control the heater and air conditioner "AUTO" mode. The resistance of the cooler thermistor (front room temperature sensor) changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies voltage (5 V) to the cooler thermistor (front room temperature sensor) and reads voltage changes as the resistance of the cooler thermistor (front room temperature sensor) changes. This sensor also sends the appropriate signals to the air conditioning amplifier.

DTC Code
DTC Detection Condition
Trouble Area
B1411/11
Open or short in room temperature sensor circuit
  1. Cooler thermistor (front room temperature sensor)
  2. Harness or connector between cooler thermistor (front room temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM


E147166E03


INSPECTION PROCEDURE

1.READ VALUE USING TECHSTREAM (ROOM TEMPERATURE SENSOR)
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Air Conditioner / Data List / Room Temperature Sensor.

  1. According to the display on the Techstream, read the Data List.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual room temperature is displayed
    Open in circuit: -6.5°C (20.3°F)
    Short in circuit: 57.25°C (135.05°F)

    OK:
    The display is as specified in the normal condition.


    Result 
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC output)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2.INSPECT COOLER THERMISTOR (FRONT ROOM TEMPERATURE SENSOR)


    E117004E19
  1. Remove the cooler thermistor (front room temperature sensor) (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    10°C (50°F)
    3.00 to 3.73 kΩ
    15°C (59°F)
    2.45 to 2.88 kΩ
    20°C (68°F)
    1.95 to 2.30 kΩ
    25°C (77°F)
    1.60 to 1.80 kΩ
    30°C (86°F)
    1.28 to 1.47 kΩ
    35°C (95°F)
    1.00 to 1.22 kΩ
    40°C (104°F)
    0.80 to 1.00 kΩ
    45°C (113°F)
    0.65 to 0.85 kΩ
    50°C (122°F)
    0.50 to 0.70 kΩ
    55°C (131°F)
    0.44 to 0.60 kΩ
    60°C (140°F)
    0.36 to 0.50 kΩ

    HINT:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.
    3. As the temperature increases, the resistance decreases (See the graph).

  1. Reinstall the cooler thermistor (front room temperature sensor).



NG
REPLACE COOLER THERMISTOR (FRONT ROOM TEMPERATURE SENSOR) (Click here)
OK


3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)


    E127562E03
  1. Disconnect the H16 cooler thermistor (front room temperature sensor) connector.

  1. Disconnect the H24 air conditioning amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H16-1 - H24-29 (TR)
    Always
    Below 1 Ω
    H16-2 - H24-34 (SG-1)
    Always
    Below 1 Ω
    H16-1 or H24-29 (TR) - Body ground
    Always
    10 kΩ or higher
    H16-2 or H24-34 (SG-1) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the air conditioning amplifier connector.

  1. Reconnect the cooler thermistor (front room temperature sensor) connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER (Click here)