Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

AIR CONDITIONING SYSTEM > Blower Motor Circuit

for Preparation Click here


DESCRIPTION

The blower motor is operated by signals from the air conditioning amplifier. Blower motor speed signals are transmitted by changes in the duty ratio.
Duty Ratio:
E132503E03
The duty ratio is the ratio of the blower motor OFF time (B) to the total of the blower motor ON and OFF time (A + B).
The blower motor controller controls the blower motor speed.

WIRING DIAGRAM


E161569E01


INSPECTION PROCEDURE

1.PERFORM ACTIVE TEST USING TECHSTREAM (BLOWER MOTOR)
  1. Connect the Techstream to DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Air Conditioner / Active Test/ Blower Motor

  1. According to the display on the Techstream, check blower motor operation while performing the Active Test.

    Air Conditioner 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -
    Result 
    Result
    Proceed to
    NG (blower motor does not operate)
    A
    NG (blower motor operates but does not change speed)
    B
    OK
    C



B
Go to step 5

C
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)
A


2.INSPECT FUSE (HTR)


    E161570E05
  1. Remove the HTR fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    HTR fuse
    Always
    Below 1 Ω

  1. Reinstall the HTR fuse.



NG
REPLACE FUSE
OK


3.CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY AND BODY GROUND)
E146411E02
  1. Disconnect the H41 blower motor connector.

  1. Measure the resistance and voltage according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H41-3 (GND) - Body ground
    Always
    Below 1 Ω

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    H41-1 (+B) - Body ground
    Always
    11 to 14 V

  1. Reconnect the blower motor connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - BLOWER MOTOR)
E161571E01
  1. Disconnect the H24 air conditioning amplifier connector.

  1. Disconnect the H41 blower motor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    H24-23 (BLW) - H41-2 (S1)
    Always
    Below 1 Ω
    H24-23 (BLW) or H41-2 (S1) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the blower motor connector.

  1. Reconnect the air conditioning amplifier connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK BLOWER MOTOR (S1 VOLTAGE)
E124470E55
  1. Disconnect the H24 air conditioning amplifier connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    H24-23 (BLW) - Body ground
    Ignition switch ON
    4.5 to 5.5 V

  1. Reconnect the air conditioning amplifier connector.



NG
REPLACE BLOWER MOTOR (Click here)
OK


6.INSPECT AIR CONDITIONING AMPLIFIER (BLW VOLTAGE)
E127572E05
  1. Remove the air conditioning amplifier with its connectors still connected (Click here).

  1. Turn the ignition switch to ON.

  1. Turn the blower switch to LO.

  1. Using an oscilloscope, check the waveform.
    Blower Motor Control Signal 
    Terminal Name
    BLW - GND
    Tester Range
    1 V/DIV, 500 μsec./DIV
    Condition
    Ignition switch ON
    Blower switch LO

    HINT:
    Waveform varies with the blower level.

  1. Reinstall the air conditioning amplifier.



NG
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)