DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
| DTC Code | DTC Detection Condition | Trouble Area |
| P2716 | Open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
|
| Related DTCs | P2716: Shift solenoid valve SLT/Range check |
| Required sensors/Components | Shift solenoid valve SLT |
| Frequency of operation | Continuous |
| Duration | 1 second |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Solenoid current cut status | Not cut |
| Battery voltage | 11 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Output signal monitor | No signal |
| Output signal duty | Less than 100% |

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
![]() |
Disconnect the D73 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 18 (SLT+) - 7 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 18 (SLT+) - Body ground | Always | 10 kΩ or higher |
| 7 (SLT-) - Body ground | Always | 10 kΩ or higher |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the D56 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D56-9 (SLT+) - D56-8 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D56-9 (SLT+) - Body ground | Always | 10 kΩ or higher |
| D56-8 (SLT-) - Body ground | Always | 10 kΩ or higher |
| *a | Front view of wire harness connector (to ECM) |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
| Valve moves and makes an operating noise |
| *a | Component without harness connected (Shift Solenoid Valve SLT) |
|
| ||||
| OK | ||
| ||