DTC P0604 Random Access Memory (RAM) |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0604 | ECM RAM errors (1 trip detection logic) | ECM |
| Related DTCs | None |
| Required sensors/Components (Main) | ECM |
| Required sensors/Components (Related) | None |
| Frequency of operation | Continuous |
| Duration | 16 seconds |
| MIL operation | Immediate |
| Sequence of operation | None |
| Monitor runs whenever following DTCs not present | None |
| Main CPU and sub CPU mirroring | Fail |
| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.CHECK FOR DTC |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Clear DTCs (Click here).
Turn the Techstream off.
Turn the ignition switch off.
Disconnect the Techstream.
Disconnect the cable from the negative (-) battery terminal and wait for 1 minute.
Connect the cable to the negative (-) battery terminal.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Wait 16 seconds or more.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Check for DTCs.
|
| ||||
| OK | ||
| ||