DTC B1835/58 Short in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1836/58 Open in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1837/58 Short to GND in Front Passenger Side Curtain Shield Squib Circuit |
DTC B1838/58 Short to B+ in Front Passenger Side Curtain Shield Squib Circuit |
| DTC Code | Detection Condition | Trouble Area |
| B1835/58 | When one of following conditions is met:
|
|
| B1836/58 | When one of following conditions is met:
|
|
| B1837/58 | When one of following conditions is met:
|
|
| B1838/58 | When one of following conditions is met:
|
|

| 1.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connector is properly connected to the curtain shield airbag RH.
Disconnect the connector from the curtain shield airbag RH.
Check that the No. 2 floor wire connector (on the curtain shield airbag RH side) is not damaged.
|
| ||||
| OK | |
| 2.CHECK CURTAIN SHIELD AIRBAG RH (CURTAIN SHIELD SQUIB RH) |
![]() |
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||
| 3.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the connector is properly connected to the center airbag sensor assembly.
Disconnect the connector from the center airbag sensor assembly.
Check that the terminal of the connector is not damaged.
Check that the short spring for the No. 2 floor wire connector with the activation prevention mechanism is not deformed or damaged.
|
| ||||
| OK | |
| 4.CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT) |
![]() |
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| P2-2 (ICR+) - Body ground | Ignition switch ON | Below 1 V |
| P2-1 (ICR-) - Body ground | Ignition switch ON | Below 1 V |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P2-2 (ICR+) - P2-1 (ICR-) | Always | Below 1 Ω |
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P2-2 (ICR+) - P2-1 (ICR-) | Always | 1 MΩ or higher |
| P2-2 (ICR+) - Body ground | Always | 1 MΩ or higher |
| P2-1 (ICR-) - Body ground | Always | 1 MΩ or higher |
|
| ||||
| OK | |
| 5.CHECK CENTER AIRBAG SENSOR |
![]() |
Restore the released activation prevention mechanism of connector B to the original condition.
Connect the connectors to the curtain shield airbag RH and the center airbag sensor.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
|
| ||||
| OK | ||
| ||