BACK DOOR CLOSER SYSTEM > Back Door Closer does not Operate |

| 1.CHECK BACK DOOR LOCK FUNCTION |
Check if the back door is fully closed by hand.
|
| ||||
| OK | |
| 2.INITIALIZE POWER BACK DOOR ECU |
Check that the power back door drive unit (power back door ECU) can be initialized (Click here).
| NEXT | |
| 3.CHECK BACK DOOR CLOSER SYSTEM |
Check that the back door closer system operates normally.
|
| ||||
| OK | ||
| ||
| 4.CHECK DTC OUTPUT |
Check for the DTCs (Click here).
| Result | Proceed to |
| DTC is not output | A |
| B2250 is output | B |
| B2251 is output | C |
|
| ||||
|
| ||||
| A | |
| 5.INSPECT FUSES (ECU-IG NO. 2, ECU-B1, PBD) |
![]() |
Remove the ECU-IG No. 2, ECU-B1, and PBD fuses.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| ECU-IG No. 2 | Always | Below 1 Ω |
| ECU-B1 | Always | Below 1 Ω |
| PBD | Always | Below 1 Ω |
Reinstall the fuses.
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (POWER SOURCE) |
Disconnect the O30 power back door ECU connector.
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O30-8 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| O30-10 (ECUB) - Body ground | Always | 11 to 14 V |
| O30-12 (B) - Body ground | Always | 11 to 14 V |
Reconnect the power back door ECU connector.
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (BODY GROUND) |
Disconnect the O30 power back door ECU connector.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| O30-11 (GND) - Body ground | Always | Below 1 Ω |
Reconnect the power back door ECU connector.
|
| ||||
| OK | |
| 8.INSPECT BACK DOOR LOCK |

Remove the back door lock (Click here).
Apply battery voltage and check the operation of the door lock motor.
| Measurement Condition | Specified Condition |
| Battery positive (+) → Terminal 2 (ACT-) Battery negative (-) → Terminal 1 (ACT+) | Latch turns to open-latch position |
| Battery positive (+) → Terminal 1 (ACT+) Battery negative (-) → Terminal 2 (ACT-) | Latch turns to full-latch position |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Door Lock Latch Position | Specified Condition |
| 5 (CLS) - 3 (E) | Over-latch | Below 1 Ω |
| 5 (CLS) - 3 (E) | Open-latch | 10 kΩ or higher |
| 5 (CLS) - 3 (E) | Full-latch | 10 kΩ or higher |
| 5 (CLS) - 3 (E) | Half-latch | 10 kΩ or higher |
| Tester Connection | Door Lock Latch Position | Specified Condition |
| 6 (S) - 3 (E) | Over-latch | 10 kΩ or higher |
| 6 (S) - 3 (E) | Open-latch | Below 1 Ω |
| 6 (S) - 3 (E) | Full-latch | 10 kΩ or higher |
| 6 (S) - 3 (E) | Half-latch | Below 1 Ω |
|
| ||||
| OK | |
| 9.CHECK HARNESS AND CONNECTOR (BACK DOOR LOCK - POWER BACK DOOR ECU AND BODY GROUND) |
![]() |
Disconnect the V5 door lock connector.
Disconnect the O30 ECU connector.
Disconnect the V2 and V3 ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| V5-2 (ACT-) - O30-2 (DC+) | Always | Below 1 Ω |
| V5-1 (ACT+) - O30-1 (DC-) | Always | Below 1 Ω |
| V5-5 (CLS) - O30-22 (HAF) | Always | Below 1 Ω |
| V5-6 (S) - V3-10 (BDCY) | Always | Below 1 Ω |
| V5-3 (E) - V3-20 (CTYE) | Always | Below 1 Ω |
| V2-17 (OCTY) - O30-20 (FULL) | Always | Below 1 Ω |
| O30-2 (DC+) - Body ground | Always | 10 kΩ or higher |
| O30-1 (DC-) - Body ground | Always | 10 kΩ or higher |
| O30-22 (HAF) - Body ground | Always | 10 kΩ or higher |
| O30-20 (FUL) - Body ground | Always | 10 kΩ or higher |
Reconnect the door lock and ECU connector.
|
| ||||
| OK | |
| 10.REPLACE POWER BACK DOOR DRIVE UNIT (POWER BACK DOOR ECU) |
Temporarily replace the power back door drive unit (power back door ECU) with a new or normally functioning one (Click here).
| NEXT | |
| 11.CHECK BACK DOOR CLOSER SYSTEM (OPERATION) |
Check that the back door closer operates normally.
|
| ||||
| OK | ||
| ||