DTC P0403 Exhaust Gas Recirculation Control Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0403 | Open or short in EGR valve circuit (1 trip detection logic) |
|
| Related DTCs | P0403: Exhaust gas recirculation control circuit range check |
| Required Sensors/Components (Main) | EGR valve |
| Required Sensors/Components (Related) | - |
| Frequency of Operation | Continuous |
| Duration | 1 second |
| MIL Operation | Immediate |
| Sequence of Operation | None |
| Monitor runs whenever following DTCs not present | None |
| Engine | Running |
| Battery voltage | 10.5 V or higher |
| Starter | OFF |
| One of the following conditions is met: | Condition 1, 2, 3 or 4 |
| 1: Both conditions are met: | Condition A and B |
| A: Motor phase 1 output terminal voltage | Low |
| B: Either condition is met: | - |
| Motor | Driving |
| Motor phase 1 | Not operating |
| 2: Both conditions are met: | Condition A and B |
| A: Motor phase 2 output terminal voltage | Low |
| B: Either condition is met: | - |
| Motor | Driving |
| Motor phase 2 | Not operating |
| 3: Both conditions are met: | Condition A and B |
| A: Motor phase 3 output terminal voltage | Low |
| B: Either condition is met: | - |
| Motor | Driving |
| Motor phase 3 | Not operating |
| 4: Both conditions are met: | Condition A and B |
| A: Motor phase 4 output terminal voltage | Low |
| B: Either condition is met: | - |
| Motor | Driving |
| Motor phase 4 | Not operating |

| Techstream Display | Description |
| NORMAL |
|
| ABNORMAL |
|
| INCOMPLETE |
|
| N/A |
|
| 1.PERFORM ACTIVE TEST USING TECHSTREAM (OPERATE EGR VALVE) |
Connect the Techstream to the DLC3.
Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the EGR Step Position.
Confirm the Throttle Idle Position is ON and check the engine idling condition and MAP values in the Data List while performing the Active Test.
| - | EGR Step Position (Active Test) | |
| 0 Steps | 0 to 30 Steps | |
| Idling condition | Steady idling | Idling changes from steady to rough idling or engine stall |
| MAP (Data List) | 20 to 40 kPa (150 to 300 mmHg, 6 to 12 in.Hg) | MAP value is at least +10 kPa (75 mmHg, 3 in.Hg) higher than when EGR valve is fully closed |
|
| ||||
| OK | ||
| ||
| 2.INSPECT EGR VALVE ASSEMBLY |
Inspect the EGR valve assembly (Click here).
|
| ||||
| OK | |
| 3.INSPECT EGR VALVE ASSEMBLY (+B OR +B2 VOLTAGE) |
![]() |
Disconnect the EGR valve assembly connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D74-5 (+B1) - Body ground | Ignition switch ON | 11 to 14 V |
| D74-2 (+B2) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to EGR valve assembly) |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (ECM - EGR VALVE ASSEMBLY) |
Disconnect the EGR valve assembly connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D56-48 (EGR1) - D74-4 (EGR1) | Always | Below 1 Ω |
| D56-1 (EGR2) - D74-3 (EGR2) | Always | Below 1 Ω |
| D56-24 (EGR3) - D74-6 (EGR3) | Always | Below 1 Ω |
| D56-47 (EGR4) - D74-1 (EGR4) | Always | Below 1 Ω |
| D56-48 (EGR1) or D74-4 (EGR1) - Body ground | Always | 10 kΩ or higher |
| D56-1 (EGR2) or D74-3 (EGR2) - Body ground | Always | 10 kΩ or higher |
| D56-24 (EGR3) or D74-6 (EGR3) - Body ground | Always | 10 kΩ or higher |
| D56-47 (EGR4) or D74-1 (EGR4) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 5.CHECK WHETHER DTC OUTPUT RECURS (DTC P0403) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Clear DTCs (Click here).
Drive the vehicle in accordance with the driving pattern described in the Confirmation Driving Pattern.
Confirm that no DTC is set using the Techstream.
| Result | Proceed to |
| DTC P0403 is output | A |
| DTC is not output | B |
|
| ||||
| A | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - EGR VALVE ASSEMBLY) |
Disconnect the EGR valve assembly connector.
Remove the integration relay from engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1B-4 - D74-5 (+B1) | Always | Below 1 Ω |
| 1B-4 - D74-2 (+B2) | Always | Below 1 Ω |
| 1B-4 or D74-5 (+B1) - Body ground | Always | 10 kΩ or higher |
| 1B-4 or D74-2 (+B2) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||