Home › Audio/Visual/Telematics › PARK ASSIST / MONITORING › BLIND SPOT MONITOR SYSTEM

BLIND SPOT MONITOR SYSTEM > Power Source Circuit

for Preparation Click here


DESCRIPTION

This circuit provides power to operate the blind spot monitor sensors.

WIRING DIAGRAM


E224413E02


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.READ VALUE USING TECHSTREAM
  1. Connect the Techstream to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the Techstream on.

  1. Enter the following menus: Body Electrical / Blind Spot Monitor Master or Blind Spot Monitor Slave / Data List.

  1. According to the display on the Techstream, read the Data List.

    Blind Spot Monitor Master 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Power Supply Voltage
    Power supply voltage / Min.: 0 V, Max.: 50 V
    11 to 14 V
    -

    Blind Spot Monitor Slave 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Power Supply Voltage
    Power supply voltage / Min.: 0 V, Max.: 50 V
    11 to 14 V
    -
    Result 
    Result
    Proceed to
    The power supply voltages of the master and slave side sensors of the blind spot monitor system are both normal.
    A
    The power supply voltage of the master side sensor of the blind spot monitor system is abnormal.
    B
    The power supply voltage of the slave side sensor of the blind spot monitor system is abnormal.
    C



B
Go to step 2

C
Go to step 4
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BATTERY)
  1. Disconnect the P25 blind spot monitor sensor RH connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    P25-5 (BRB) - Body ground
    Ignition switch ON
    11 to 14 V
    P25-5 (BRB) - Body ground
    Ignition switch off
    Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND)
  1. Disconnect the P25 blind spot monitor sensor RH connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P25-1 (BRGD) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BLIND SPOT MONITOR SENSOR RH (Click here)  

4.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BATTERY)
  1. Disconnect the O46 blind spot monitor sensor LH connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    O46-5 (BLB) - Body ground
    Ignition switch ON
    11 to 14 V
    O46-5 (BLB) - Body ground
    Ignition switch off
    Below 1 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)
  1. Disconnect the O46 blind spot monitor sensor LH connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    O46-1 (BLGD) - Body ground
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE BLIND SPOT MONITOR SENSOR LH (Click here)