BLIND SPOT MONITOR SYSTEM > Main Switch Circuit |

| 1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| BSM Main SW | Blind spot monitor main switch assembly (warning canceling switch assembly) / OFF or ON | ON: Blind spot monitor main switch assembly (warning canceling switch assembly) on OFF: Blind spot monitor main switch assembly (warning canceling switch assembly) off | - |
| Result | Proceed to |
| The display changes as shown above when the blind spot monitor main switch assembly (warning canceling switch assembly) is operated. | A |
| The display does not change as shown above when the blind spot monitor main switch assembly (warning canceling switch assembly) is operated. | B |
|
| ||||
| A | ||
| ||
| 2.INSPECT BLIND SPOT MONITOR MAIN SWITCH ASSEMBLY (WARNING CANCELING SWITCH ASSEMBLY) |
![]() |
Remove the blind spot monitor main switch assembly (warning canceling switch assembly) (Click here).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 11 (B) - 8 (D) | Blind spot monitor main switch is on | Below 1 Ω |
| 11 (B) - 8 (D) | Blind spot monitor main switch is off | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - BATTERY) |
Disconnect the H121 blind spot monitor main switch assembly (warning canceling switch assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| H121-11 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| H121-11 (B) - Body ground | Ignition switch off | Below 1 V |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR MAIN SWITCH - BLIND SPOT MONITOR SENSOR RH) |
Disconnect the P25 blind spot monitor sensor RH connector.
Disconnect the H121 blind spot monitor main switch assembly (warning canceling switch assembly) connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P25-3 (BSSW) - H121-8 (D) | Always | Below 1 Ω |
| P25-3 (BSSW) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||