DTC    P0116    Engine Coolant Temperature Circuit Range / Performance Problem

for Preparation Click here


DESCRIPTION

Refer to DTC P0115 .

DTC No.
DTC Detection Condition
Trouble Area
P0116
Engine Coolant Temperature (ECT) between 35°C and 60°C (95°F and 140°F) when engine started, and conditions (a) and (b) met (2 trip detection logic)
(a) Vehicle driven at varying speeds (accelerated and decelerated)
(b) ECT remains within 3°C (5.4°F) of initial ECT
  1. Thermostat
  2. ECT sensor

MONITOR DESCRIPTION

  1. Engine coolant temperature (ECT) sensor high side stuck monitor
    The ECM monitors the sensor voltage and uses this value to calculate the ECT. If the sensor voltage output deviates from the normal operating range, the ECM interprets this deviation as a malfunction in the ECT sensor and sets the DTC.
    Examples:
    1. Upon starting the engine, the ECT is between 35°C and 60°C (95°F and 140°F). If after driving for 250 seconds, the ECT remains within 3°C (5.4°F) of the starting temperature, the DTC is set (2 trip detection logic).

INSPECTION PROCEDURE

HINT:
  1. If any of DTCs P0115, P0117 or P0118 are stored simultaneously with DTC P0116, the ECT sensor may have an open or a short circuit. Troubleshoot those DTCs first.
  2. Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTC.
    Result 
    Result
    Proceed to
    P0116 is output
    A
    P0116 and other DTCs are output
    B



B
GO TO DTC CHART (Click here)
A


2.INSPECT THERMOSTAT
  1. Remove the thermostat (Click here).

  1. Measure the valve opening temperature of the thermostat.

    Standard opening temperature:
    80 to 84°C (176 to 183°F)

    HINT:
    In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.

  1. Reinstall the thermostat (Click here).



NG
REPLACE THERMOSTAT (Click here)
OK

REPLACE ENGINE COOLANT TEMPERATURE SENSOR (Click here)