DTC P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) |
DTC P0032 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 1 Sensor 1) |
DTC P0051 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 2 Sensor 1) |
DTC P0052 Oxygen (A/F) Sensor Heater Control Circuit High (Bank 2 Sensor 1) |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0031 P0051 | Air-Fuel Ratio (A/F) sensor heater current less than 0.8 A (1 trip detection logic) |
|
| P0032 P0052 | Air-Fuel Ratio (A/F) sensor heater current failure (1 trip detection logic) |
|
| 1.INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE) |
![]() |
Disconnect the A/F sensor connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (HA1A) - 2 (+B) | 20°C (68°F) | 1.8 to 3.4 Ω |
| 1 (HA1A) - 4 (A1A-) | Always | 10 kΩ or higher |
| 1 (HA2A) - 2 (+B) | 20°C (68°F) | 1.8 to 3.4 Ω |
| 1 (HA2A) - 4 (A2A-) | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK TERMINAL VOLTAGE (+B OF A/F SENSOR) |
![]() |
Disconnect the A/F sensor connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D19-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| D20-2 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| Result | Proceed to |
| NG | A |
| OK | B |
|
| ||||
| A | |
| 3.INSPECT INTEGRATION RELAY (A/F) |
![]() |
Remove the integration relay from the engine room relay block.
Inspect the A/F fuse.
Remove the A/F fuse from the integration relay.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A/F fuse | Always | Below 1 Ω |
Reinstall the A/F fuse.
Inspect the integration relay (A/F).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1C-1 - 1A-4 | When no battery voltage applied to terminals 1A-2 and 1A-3 | 10 kΩ or higher |
| When battery voltage applied to terminals 1A-2 and 1A-3 | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - A/F SENSOR AND BODY GROUND) |
![]() |
Disconnect the A/F sensor connector.
Remove the integration relay from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D19-2 (+B) - 1A-4 | Always | Below 1 Ω |
| D20-2 (+B) - 1A-4 | Always | Below 1 Ω |
| 1A-2 - 1B-5 | Always | Below 1 Ω |
| 1A-3 - Body ground | Always | Below 1 Ω |
| D19-2 (+B) or 1A-4 - Body ground | Always | 10 kΩ or higher |
| D20-2 (+B) or 1A-4 - Body ground | Always | 10 kΩ or higher |
| 1A-2 or 1B-5 - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (A/F SENSOR - ECM) |
![]() |
Disconnect the A/F sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D19-1 (HA1A) - D56-22 (HA1A) | Always | Below 1 Ω |
| D20-1 (HA2A) - D56-20 (HA2A) | Always | Below 1 Ω |
| D19-1 (HA1A) or D56-22 (HA1A) - Body ground | Always | 10 kΩ or higher |
| D20-1 (HA2A) or D56-20 (HA2A) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | |
| 6.CHECK WHETHER DTC OUTPUT RECURS |
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Clear DTCs (Click here).
Start the engine.
Allow the engine to idle for 1 minute or more.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read DTCs.
| Result | Proceed to |
| No DTC is output | A |
| P0031, P0032, P0051 or P0052 is output | B |
|
| ||||
| A | ||
| ||