Home › Vehicle Interior › SUPPLEMENTAL RESTRAINT SYSTEMS › AIRBAG SYSTEM

DTC    B1835/58    Short in Front Passenger Side Curtain Shield Squib Circuit

DTC    B1836/58    Open in Front Passenger Side Curtain Shield Squib Circuit

DTC    B1837/58    Short to GND in Front Passenger Side Curtain Shield Squib Circuit

DTC    B1838/58    Short to B+ in Front Passenger Side Curtain Shield Squib Circuit

for Preparation Click here


DESCRIPTION

The curtain shield squib RH circuit consists of the center airbag sensor and the curtain shield airbag RH.
The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib RH circuit.

DTC Code
Detection Condition
Trouble Area
B1835/58
When one of following conditions is met:
  1. The center airbag sensor receives a line short circuit signal 5 times in the curtain shield squib RH circuit during primary check.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor malfunction
  1. No. 2 floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1836/58
When one of following conditions is met:
  1. The center airbag sensor receives an open circuit signal in the curtain shield squib RH circuit for 2 seconds.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor malfunction
  1. No. 2 floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1837/58
When one of following conditions is met:
  1. The center airbag sensor receives a short circuit to ground signal in the curtain shield squib RH circuit for 0.5 seconds.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor malfunction
  1. No. 2 floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly
B1838/58
When one of following conditions is met:
  1. The center airbag sensor receives a short circuit to B+ signal in the curtain shield squib RH circuit for 0.5 seconds.
  2. Curtain shield squib RH malfunction
  3. Center airbag sensor malfunction
  1. No. 2 floor wire
  2. Curtain shield airbag assembly RH (Curtain shield squib RH)
  3. Center airbag sensor assembly

WIRING DIAGRAM


C157591E58


INSPECTION PROCEDURE

NOTICE:
  1. After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work (Click here).
  2. When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).

HINT:
  1. Perform the simulation method by selecting "check mode" (signal check) with the intelligent tester (Click here).
  2. After selecting "check mode" (signal check), perform the simulation method by wiggling each connector of the airbag system or driving the vehicle on various types of roads (Click here).

1.CHECK CONNECTOR
  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Check that the connector is properly connected to the curtain shield airbag RH.

    OK:
    The connector is properly connected.

    HINT:
    If the connector is not connected securely, reconnect the connector and proceed to the next inspection.

  1. Disconnect the connector from the curtain shield airbag RH.

  1. Check that the No. 2 floor wire connector (on the curtain shield airbag RH side) is not damaged.

    OK:
    The lock button is not disengaged, or the claw of the lock is not deformed or damaged.



NG
REPLACE NO. 2 FLOOR WIRE
OK


2.CHECK CURTAIN SHIELD AIRBAG RH (CURTAIN SHIELD SQUIB RH)
C179163E01
  1. Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.

    CAUTION:
    Never connect the tester to the curtain shield airbag RH (curtain shield squib RH) for measurement, as this may lead to a serious injury due to airbag deployment.

    NOTICE:
    1. Do not forcibly insert SST into the terminals of the connector when connecting SST.
    2. Insert SST straight into the terminals of the connector.

SST
09843-18061  
  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1835, B1836, B1837, B1838 or 58 is not output.

    HINT:
    Codes other than DTCB1835, B1836, B1837, B1838 and 58 may be output at this time, but they are not related to this check.



NG
Go to step 3
OK

REPLACE CURTAIN SHIELD AIRBAG ASSEMBLY RH (Click here)  

3.CHECK CONNECTOR
  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Disconnect SST from connector C.

  1. Check that the connector is properly connected to the center airbag sensor assembly.

    OK:
    The connector is properly connected.

    HINT:
    If the connector is not connected securely, reconnect the connector and proceed to the next inspection.

  1. Disconnect the connector from the center airbag sensor assembly.

  1. Check that the terminal of the connector is not damaged.

    OK:
    The terminal is not deformed or damaged.

  1. Check that the short spring for the No. 2 floor wire connector with the activation prevention mechanism is not deformed or damaged.

    OK:
    The short spring is not deformed or damaged.



NG
REPLACE NO. 2 FLOOR WIRE
OK


4.CHECK NO. 2 FLOOR WIRE (CURTAIN SHIELD SQUIB RH CIRCUIT)
C179164E01
  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    P2-2 (ICR+) - Body ground
    Ignition switch ON
    Below 1 V
    P2-1 (ICR-) - Body ground
    Ignition switch ON
    Below 1 V

  1. Turn the ignition switch off.

  1. Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P2-2 (ICR+) - P2-1 (ICR-)
    Always
    Below 1 Ω

  1. Release the activation prevention mechanism built into connector B (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    P2-2 (ICR+) - P2-1 (ICR-)
    Always
    1 MΩ or higher
    P2-2 (ICR+) - Body ground
    Always
    1 MΩ or higher
    P2-1 (ICR-) - Body ground
    Always
    1 MΩ or higher



NG
REPLACE NO. 2 FLOOR WIRE
OK


5.CHECK CENTER AIRBAG SENSOR ASSEMBLY
C146261E12
  1. Restore the released activation prevention mechanism of connector B to the original condition.

  1. Connect the connectors to the curtain shield airbag RH and the center airbag sensor.

  1. Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Clear the DTCs (Click here).

  1. Turn the ignition switch off.

  1. Turn the ignition switch to ON, and wait for at least 60 seconds.

  1. Check for DTCs (Click here).

    OK:
    DTC B1835, B1836, B1837, B1838 or 58 is not output.

    HINT:
    Codes other than DTC B1835, B1836, B1837, B1838 and 58 may be output at this time, but they are not related to this check.

    Result 
    Result
    Proceed to
    OK
    A
    NG (w/ Cool Box)
    B
    NG (w/o Cool Box)
    C



B
REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)

C
REPLACE CENTER AIRBAG SENSOR ASSEMBLY (Click here)
A

USE SIMULATION METHOD TO CHECK (Click here)