Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM

DTC    B1413/13    Evaporator Temperature Sensor Circuit

for Preparation Click here


DESCRIPTION

The No. 1 cooler thermistor (evaporator temperature sensor) is installed on the evaporator in the air conditioning unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor (evaporator temperature sensor) and reads voltage changes as the resistance of the No. 1 cooler thermistor (evaporator temperature sensor) changes. This sensor is used for frost prevention.

DTC Code
DTC Detection Condition
Trouble Area
B1413/13
An open or short in evaporator temperature sensor circuit.
  1. No. 1 cooler thermistor (evaporator temperature sensor)
  2. Air conditioning harness assembly
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


E147578E05


INSPECTION PROCEDURE

1.READ VALUE USING INTELLIGENT TESTER (NO. 1 COOLER THERMISTOR)
  1. Use the Data List to check if the No. 1 cooler thermistor (evaporator temperature sensor) is functioning properly.

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Evaporator Fin Thermistor
    No. 1 cooler thermistor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature is displayed
    Open in the circuit: -29.7°C (-21.46°F)
    Short in the circuit: 59.55°C (139.19°F)

    OK:
    The display is as specified in the normal condition.

    Result 
    Result
    Proceed to
    NG
    A
    OK (When troubleshooting according to Problem Symptoms Table)
    B
    OK (When troubleshooting according to the DTC output)
    C



B
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
A


2.INSPECT NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)
E115010E23
  1. Remove the No. 1 cooler thermistor (evaporator temperature sensor) (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ

    HINT:
    As the temperature increases, the resistance decreases (See the graph).

    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.



NG
REPLACE NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR) (Click here)
OK


3.CHECK AIR CONDITIONING HARNESS ASSEMBLY (EVAPORATOR TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E182380E02
  1. Remove the air conditioning harness assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (SGB) - z13-5 (SGA)
    Always
    Below 1 Ω
    2 (TEB) - z13-6 (TEA)
    Always
    Below 1 Ω
    1 (SGB) - z13-6 (TEA)
    Always
    10 kΩ or higher
    2 (TEB) - z13-5 (SGA)
    Always
    10 kΩ or higher



NG
REPLACE AIR CONDITIONING HARNESS ASSEMBLY (Click here)
OK