Home › General › CHASSIS › DIFFERENTIAL
NM27L0U _V1 General _050239 CHASSIS _0243364 DIFFERENTIAL UN GENERAL/CONTROL/DETAILS F

CHASSIS  DIFFERENTIAL  GENERAL/CONTROL/DETAILS  A.D.D. SHIFT ACTUATOR  


Construction


a.

The A.D.D. shift actuator contains the A.D.D. shift motor, limit switch and A.D.D. detection switch. It should not be disassembled.

i.

The A.D.D. state (disconnected or connected) can be determined by the combinations of the 2 contact point switches.

X129500C01
5.313,0.875 5.74,0.583 true 3.229,1.052 3.573,0.24 true 2.552,0.365 3.167,0.99 true 3.281,2.469 3.5,1.656 true 2.385,0.229 2.698,0.385 0.313,0.156 10 false *1 3.198,2.458 3.51,2.615 0.313,0.156 10 false *2 5.771,0.448 6.083,0.604 0.313,0.156 10 false *3 3.531,0.063 3.844,0.219 0.313,0.156 10 false *4
*1 Limit Switch (DL1) *2 A.D.D. Detection Switch
*3 A.D.D. Shift Motor *4 Limit Switch (DL2)


Combinations of 2 Contact Point Switches
X129501E01
4.031,0.26 4.823,0.594 0.792,0.333 10 false Connect 2.458,0.271 3.25,0.604 0.792,0.333 10 false Disconnect 2.25,0.729 3.042,1.063 0.792,0.333 10 false On 2.25,1.24 3.042,1.573 0.792,0.333 10 false Off 2.26,1.76 3.052,2.094 0.792,0.333 10 false On 2.271,2.26 3.063,2.594 0.792,0.333 10 false Off 1.875,0.958 2.667,1.292 0.792,0.333 10 false DL1 1.865,2 2.656,2.333 0.792,0.333 10 false DL2