RM27L0U
_V1
General
_049291
SPECIFICATIONS
_0235459
BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS
F
SPECIFICATIONS BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS SERVICE DATA
VSC OFF Switch
| Item
|
Tester Connection
|
Switch Condition
|
Specified Condition
|
| VSC OFF switch
|
6 - 9
|
Pressed
|
Below 1 Ω
|
| Not pressed
|
10 kΩ or higher
|
Stop Light Control Relay (for BRK NO. 1)
| Tester Connection
|
Switch Condition
|
Specified Condition
|
| 3 - 4
|
Battery voltage applied to terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage not applied to terminals 1 and 2
|
Below 1 Ω
|
| 3 - 5
|
Battery voltage not applied to terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage applied to terminals 1 and 2
|
Below 1 Ω
|
Stop Light Control Relay (for BRK NO. 2)
| Tester Connection
|
Switch Condition
|
Specified Condition
|
| 3 - 4
|
Battery voltage applied to terminals 1 and 2
|
10 kΩ or higher
|
| Battery voltage not applied to terminals 1 and 2
|
Below 1 Ω
|