Home › General › SPECIFICATIONS › BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS
RM27L0U _V1 General _049291 SPECIFICATIONS _0235459 BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS F

SPECIFICATIONS  BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS  SERVICE DATA  


VSC OFF Switch
Item Tester Connection Switch Condition Specified Condition
VSC OFF switch 6 - 9 Pressed Below 1 Ω
Not pressed 10 kΩ or higher

Stop Light Control Relay (for BRK NO. 1)
Tester Connection Switch Condition Specified Condition
3 - 4 Battery voltage applied to terminals 1 and 2 10 kΩ or higher
Battery voltage not applied to terminals 1 and 2 Below 1 Ω
3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
Battery voltage applied to terminals 1 and 2 Below 1 Ω

Stop Light Control Relay (for BRK NO. 2)
Tester Connection Switch Condition Specified Condition
3 - 4 Battery voltage applied to terminals 1 and 2 10 kΩ or higher
Battery voltage not applied to terminals 1 and 2 Below 1 Ω