| Amount of change in vehicle height | HIGH position: | 30 mm (1.18 in.) |
| LOW position: | 30 mm (1.18 in.) | |
| Difference between the tester value and vehicle height
(C - D measurement): |
5 mm (0.20 in.) or less | |
| Difference between the right side and the left side | 10 mm (0.39 in.) or less | |
| Tester Connection | Sensor Condition | Specified Condition |
| for LH side
2 (SHRL) - 1 (SHG) |
High (45°) | 3.60 to 4.52 V |
| Normal (0°) | 2.06 to 2.45 V | |
| Low (-45°) | 0.40 to 0.51 V | |
| for RH side
2 (SHRR) - 1 (SHG) |
High (45°) | 3.60 to 4.52 V |
| Normal (0°) | 2.06 to 2.45 V | |
| Low (-45°) | 0.40 to 0.51 V |
| Tester Connection | Sensor Condition | Specified Condition |
| for LH side
1 (SGRR) - 2 (SGND) |
Sensor stationary | Approx. 2.0 to 2.5 V |
| Sensor is tilted | Change between approx. 0.9 to 2.3 V | |
| for RH side
1 (SGFL) - 2 (SHG) |
Sensor stationary | Approx. 2.0 to 2.5 V |
| Sensor is tilted | Change between approx. 0.9 to 2.3 V |
| Tester Connection | Sensor Condition | Specified Condition |
| 1 (FAL+) - 2 (FAL-) | Always | 6.4 to 7.2 Ω |
| 3 (FBL-) - 4 (FBL+) | Always | 6.4 to 7.2 Ω |
| 1 (FAR+) - 2 (FAR-) | Always | 6.4 to 7.2 Ω |
| 3 (FBR-) - 4 (FBLR+) | Always | 6.4 to 7.2 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| 9 (ECU1) - 7 (GND) | SPORT position | Below 1 Ω |
| Normal position | 10 kΩ or higher | |
| 8 (ECU2) - 7 (GND) | COMFORT position | Below 1 Ω |
| Normal position | 10 kΩ or higher |