This DTC is designed to detect opens or shorts in the Camshaft Timing Oil Control Valve Assembly (OCV) circuit. If the OCV's duty-cycle is excessively high or low while the engine is running, the ECM will illuminate the MIL and set the DTC.
The VVT (variable valve timing) system adjusts the exhaust valve timing to improve the driveability. The engine oil pressure turns the camshaft actuator to adjust the valve timing. The OCV is a solenoid valve and switches the engine oil line. The valve moves when the ECM applies 12 volts to the solenoid. The ECM changes the energizing time to the solenoid (duty-cycle) in accordance with the camshaft position, crankshaft position, throttle position, etc.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0013 | Open or short in OCV (for exhaust side of bank 1) circuit
(1 trip detection logic) |
·
Open or short in OCV (for exhaust side of bank 1) circuit ·
OCV (for exhaust side of bank 1) ·
ECM |
| P0023 | Open or short in OCV (for exhaust side of bank 2) circuit
(1 trip detection logic) |
·
Open or short in OCV (for exhaust side of bank 2) circuit ·
OCV (for exhaust side of bank 2) ·
ECM |
This DTC is designed to detect opens or shorts in the Camshaft Timing Oil Control Valve Assembly (OCV) circuit. If the OCV's duty-cycle is excessively high or low while the engine is running, the ECM will illuminate the MIL and set the DTC.
| Related DTCs | P0013: Exhaust camshaft OCV (for Bank 1)
P0023: Exhaust camshaft OCV (for Bank 2) |
| Required sensors/Components (Main) | Camshaft timing oil control valve (for exhaust side) |
| Required sensors/Components (Related) | - |
| Frequency of operation | Continuous |
| Duration | 1 second |
| MIL operation | Immediate |
| Sequence of operation | None |
| Monitor runs whenever following DTCs not stored | None |
| All of following conditions met | - |
| Starter | OFF |
| Ignition switch | ON |
| Time after ignition switch off to ON | 0.5 seconds or more |
| One of following conditions met | - |
| A. All of following conditions met | - |
| Battery voltage | 11 to 13 V |
| Target duty cycle | Less than 70% |
| B. All of following conditions met | - |
| Battery voltage | 13 V or more |
| Target duty cycle | Less than 80% |
| Current cut status | Not cut |
| Output duty cycle | 100% or more |
| Output duty cycle | 3% or less |
| OCV duty-cycle | 3 to 100% when engine running |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON and turn the Techstream on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the Techstream on.
Wait 5 seconds.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Read Pending DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0013 or P0023.
Check the DTC judgment result.
| Tester Display | Description |
|---|---|
| NORMAL | ·
DTC judgment completed ·
System normal |
| ABNORMAL | ·
DTC judgment completed ·
System abnormal |
| INCOMPLETE | ·
DTC judgment not completed ·
Perform driving pattern after confirming DTC enabling conditions |
| N/A | ·
Unable to perform DTC judgment ·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).
If a permanent DTC is output, the system is malfunctioning.
If no permanent DTC is output, the system is normal.
If DTC P0013 is displayed, check the bank 1 VVT system for exhaust camshaft circuit.
Bank 1 refers to the bank that includes the No. 1 cylinder*.
*: The No. 1 cylinder is the cylinder which is farthest from the transmission.
If DTC P0023 is displayed, check the bank 2 VVT system for exhaust camshaft circuit.
Bank 2 refers to the bank that does not include the No. 1 cylinder.
Read freeze frame data using the Techstream. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was moving or stationary, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
Connect the Techstream to the DLC3.
Clear DTC after recording the freeze frame data and DTC.
Turn the ignition switch off.
Allow the engine to idle and check DTC.
Check that P0013 or P0023 is not output.
P0013 or P0023 is not output.
OK
NG
Inspect the camshaft timing oil control valve assembly (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>CAMSHAFT OIL CONTROL VALVE>INSPECTION).
OK
NG
Disconnect the D28 or D29 camshaft timing oil control valve assembly connector.
Disconnect the D56 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D28-1 - D56-56 (OE1+) | Always | Below 1 Ω |
| D28-2 - D56-55 (OE1-) | Always | Below 1 Ω |
| D29-1 - D56-50 (OE2+) | Always | Below 1 Ω |
| D29-2 - D56-49 (OE2-) | Always | Below 1 Ω |
| D28-1 or D56-56 (OE1+) - Body ground | Always | 10 kΩ or higher |
| D28-2 or D56-55 (OE1-) - Body ground | Always | 10 kΩ or higher |
| D29-1 or D56-50 (OE2+) - Body ground | Always | 10 kΩ or higher |
| D29-2 or D56-49 (OE2-) - Body ground | Always | 10 kΩ or higher |
OK