1.INSPECT INTEGRATION RELAY (IG2)
Measure the resistance of the IG2 MAIN fuse.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IG2 MAIN fuse | Always | Below 1 Ω |
If the result is not as specified, replace the IG2 MAIN fuse.
Measure the resistance of the ignition relay No. 2 (IG2) circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - 1B-8 | Battery voltage is not applied to terminals 1B-6 and 1B-7 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1B-6 and 1B-7 | Below 1 Ω |
If the result is not as specified, replace the integration relay.
2.INSPECT INTEGRATION RELAY (EFI)
Measure the resistance of the EFI No. 1 fuse.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| EFI No. 1 fuse | Always | Below 1 Ω |
If the result is not as specified, replace the EFI No. 1 fuse.
Measure the resistance of the EFI MAIN relay circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - 1B-4 | Battery voltage is not applied to terminals 1B-2 and 1B-3 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1B-2 and 1B-3 | Below 1 Ω |
If the result is not as specified, replace the integration relay.
3.INSPECT INTEGRATION RELAY (A/F)
Measure the resistance of the A/F fuse.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A/F fuse | Always | Below 1 Ω |
If the result is not as specified, replace the A/F fuse.
Measure the resistance of the A/F sensor heater relay circuit.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - 1A-4 | Battery voltage is not applied to terminals 1A-2 and 1A-3 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1A-2 and 1A-3 | Below 1 Ω |
If the result is not as specified, replace the integration relay.
4.INSPECT FUEL PUMP RELAY
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the fuel pump relay.
5.INSPECT AIR PUMP HEATER RELAY (AI-HTR)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage is not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage is applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the air pump heater relay.