3UR-FE ENGINE CONTROL  MASS AIR FLOW METER  INSPECTION  


PROCEDURE

Hide 22204 1.INSPECT MASS AIR FLOW METER

a.

Check the output voltage.

i.
A165594E06
2.427,2.844 2.156,3.219 false 2.594,2.792 2.729,2.188 false 2.74,2.854 3.104,3.396 false 0.24,3.646 0.49,3.854 0.25,0.208 10 false Air 2.906,3.417 3.385,3.604 0.479,0.188 10 false 1 (+B) 2.75,2 3.354,2.229 0.604,0.229 10 false 2 (E2G) 1.823,3.24 2.323,3.438 0.5,0.198 10 false 3 (VG) 0.146,0.177 2.667,0.594 2.521,0.417 10 false Component without harness connected: (MAF Meter)

Apply battery voltage across terminals 1 (+B) and 2 (E2G).

NOTICE:

While using the battery during inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.



ii.

Using a voltmeter, connect the positive (+) tester probe to terminal 3 (VG), and negative (-) tester probe to terminal 2 (E2G).


iii.

Blow air into the MAF meter, and check that the voltage fluctuates.

If the result is not as specified, replace the MAF meter.



b.
A165595E02
1.944,1.488 2.834,1.902 0.891,0.414 10 Platinum Hot Wire (Heater) 1.319,2.49 1.89,1.578 false

Perform a visual check for any foreign matter on the platinum hot wire (heater) of the mass air flow meter shown in the illustration.

OK:

There is no foreign material.


If the result is not as specified, replace the mass air flow meter.


c.

Check the IAT sensor.

A379729E01
1.448,1.563 1.219,1.115 1.219,1.115 1.073,1.115 true 1.563,1.552 1.76,1.135 1.76,1.135 1.906,1.135 true 5.365,1.021 5.625,0.781 5.625,0.781 5.813,0.781 true 0.323,0.156 2.823,0.563 2.5,0.406 10 false Component without harness connected: (MAF Meter) 0.604,1.01 1.115,1.208 0.51,0.198 10 false 5 (E2) 1.979,1.031 2.531,1.229 0.552,0.198 10 false 4 (THA) 3.125,0.052 4.094,0.26 0.969,0.208 10 false Resistance kΩ 4.177,0.073 4.396,0.24 0.219,0.167 10 false 20 4.167,0.333 4.385,0.5 0.219,0.167 10 false 10 4.115,2.063 4.385,2.229 0.271,0.167 10 false 0.1 4.115,1.823 4.385,1.99 0.271,0.167 10 false 0.2 4.125,1.646 4.396,1.813 0.271,0.167 10 false 0.3 4.115,1.458 4.385,1.625 0.271,0.167 10 false 0.5 4.219,1.177 4.344,1.365 0.125,0.188 10 false 1 4.219,0.917 4.344,1.104 0.125,0.188 10 false 2 4.219,0.771 4.344,0.958 0.125,0.188 10 false 3 4.219,0.594 4.344,0.781 0.125,0.188 10 false 5 5.885,0.688 6.688,0.896 0.802,0.208 10 false Acceptable 3.052,2.302 4.385,2.5 1.333,0.198 10 false Temperature °C (°F) 4.49,2.323 4.76,2.49 0.271,0.167 10 false -20 4.885,2.323 5.042,2.49 0.156,0.167 10 false 0 5.177,2.323 5.448,2.49 0.271,0.167 10 false 20 5.51,2.323 5.781,2.49 0.271,0.167 10 false 40 5.854,2.323 6.125,2.49 0.271,0.167 10 false 60 6.198,2.323 6.469,2.49 0.271,0.167 10 false 80 6.51,2.323 6.781,2.49 0.271,0.167 10 false 100 4.49,2.479 4.76,2.646 0.271,0.167 10 false (-4) 4.802,2.479 5.115,2.667 0.313,0.188 10 false (32) 5.135,2.479 5.448,2.667 0.313,0.188 10 false (68) 5.448,2.479 5.813,2.667 0.365,0.188 10 false (104) 5.771,2.479 6.156,2.656 0.385,0.177 10 false (140) 6.115,2.479 6.5,2.656 0.385,0.177 10 false (176) 6.469,2.469 6.854,2.646 0.385,0.177 10 false (212)

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (THA) - 5 (E2) -20°C (-4°F) 12.5 k to 16.9 kΩ
20°C (68°F) 2.19 k to 2.67 kΩ
60°C (140°F) 0.50 k to 0.68 kΩ


If the result is not as specified, replace the MAF meter.