Home › Engine / Hybrid System › 3UR-FE EMISSION CONTROL › AIR PUMP
RM27L0U _51 Engine / Hybrid System _049300 3UR-FE EMISSION CONTROL _0235593 AIR PUMP G

3UR-FE EMISSION CONTROL  AIR PUMP  INSPECTION  


PROCEDURE

Hide 17610C 1.INSPECT AIR PUMP ASSEMBLY

a.

Check the heater resistance.

i.
A256388E01
0.03,0 0.218,0.172 0.188,0.172 10 *a 2.428,0.555 2.848,0.724 0.420,0.170 10 APH+ 2.385,0.635 2.265,0.635 2.265,0.635 1.938,0.867 false 2.385,1.59 2.276,1.59 2.276,1.59 1.94,1.426 false 2.413,1.499 2.871,1.669 0.458,0.170 10 APHG

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 (APH+) - 3 (APHG) -20°C (-4°F) 4.4 to 20.0 Ω
-10°C (14°F) 3.9 to 18.0 Ω
0°C (32°F) 3.5 to 16.0 Ω
10°C (50°F) 3.2 to 15.0 Ω
20°C (68°F) 3.0 to 14.0 Ω


Text in Illustration
*a Component without harness connected
(Air pump)

If the result is not as specified, replace the air pump assembly.