Home › Engine / Hybrid System › 3UR-FBE COOLING › THERMOSTAT
RM27L0U _51 Engine / Hybrid System _049303 3UR-FBE COOLING _0235614 THERMOSTAT G

3UR-FBE COOLING  THERMOSTAT  INSPECTION  


PROCEDURE

Hide 16031 1.INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

A140931

HINT:

The valve opening temperature is stamped on the water inlet with thermostat.


a.
A140932

Immerse the water inlet with thermostat in water and gradually heat the water.


b.

Check the valve opening temperature.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)


If the valve opening temperature is not within the specified range, replace the water inlet with thermostat.


c.
A140933E01
2.526,1.484 3.136,1.647 0.610,0.163 10 Valve Lift

Check the valve lift.

Standard valve lift:

10 mm (0.394 in.) or more at 95°C (203°F)


If the valve lift is not as specified, replace the water inlet with thermostat.


d.

Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)).

If it is not fully closed, replace the water inlet with thermostat.