Home › Engine / Hybrid System › 3UR-FBE STARTING › STARTER
RM27L0U _51 Engine / Hybrid System _049308 3UR-FBE STARTING _0235636 STARTER G

3UR-FBE STARTING  STARTER  INSPECTION  


PROCEDURE

Hide 28100 1.INSPECT STARTER ASSEMBLY

CAUTION:

As a large electric current passes through the cable during this inspection, a thick cable must be used. Otherwise, the cable may become hot and cause injury.


NOTICE:

These tests must be performed within 3 to 5 seconds to avoid burning out the coil.


a.

Perform a pull-in test.

i.

Remove the nut, and then disconnect the field coil lead wire from terminal C.


ii.
A258308E02
2.099,2.059 2.807,2.212 0.708,0.153 10 Terminal C 2.451,0.096 3.220,0.254 0.769,0.158 10 Terminal 50 2.144,0.74 2.32,0.193 2.32,0.193 2.434,0.193 false 2.145,1.131 2.508,1.934 2.508,1.934 2.508,2.046 false

Connect the battery to the magnet starter switch as shown in the illustration. Then check that the clutch pinion gear moves outward.

If the clutch pinion gear does not move outward, replace the magnet starter switch assembly.



b.

Perform a holding test.

i.
A258309E01
2.246,1.95 2.957,2.104 0.711,0.154 10 Terminal C 2.129,1.12 2.137,2.027 2.137,2.027 2.24,2.027 false

When the battery is connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.

If the clutch pinion gear moves inward, replace the magnet starter switch assembly.



c.

Inspect the clutch pinion gear return.

i.
A258310

Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.

If the clutch pinion gear does not return inward, replace the magnet starter switch assembly.



d.

Perform an operation test without load.

i.

Connect the field coil lead wire to terminal C with the nut.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


ii.

Mount the starter in a vise between aluminum plates.


iii.
A258311E06
2.167,0.948 2.531,1.531 2.531,1.531 2.531,1.74 false 2.031,1.031 1.76,1.958 1.76,1.958 1.76,2.052 false 1.333,2.063 2.104,2.219 0.771,0.156 10 false Terminal 30 2.208,1.76 3,2 0.792,0.24 10 true Terminal 50

Connect the battery and an ammeter to the starter as shown in the illustration.


iv.

Check that the starter rotates smoothly and steadily while the pinion gear is moving outward. Then measure the current.

Standard current:

150 A or less at 11.5 V


If the result is not as specified, replace the starter assembly.



Hide 28150 2.INSPECT MAGNET STARTER SWITCH ASSEMBLY

a.

Check if the pull-in coil has an open circuit.

i.
A162877E07
1.813,1.469 1.813,1.792 false 2.406,0.448 2.323,0.448 false 2.323,0.448 1.99,1.052 false 2.458,0.375 3.229,0.563 0.771,0.188 10 false Terminal 50 1.5,1.813 2.229,2 0.729,0.188 10 false Terminal C

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 50 - Terminal C Always Below 1 Ω


If the result is not as specified, replace the magnet starter switch assembly.



b.

Check if the holding coil has an open circuit.

i.
A162878E01
2.427,0.683 3.198,0.853 0.772,0.170 10 Terminal 50 2.386,0.775 2.295,0.775 false 2.295,0.775 2.002,1.391 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Terminal 50 - Switch body Always Below 2 Ω


If the result is not as specified, replace the magnet starter switch assembly.



Hide 28160 3.INSPECT STARTER ARMATURE ASSEMBLY

a.

Check the surface of the commutator for dirt and burns.

If the surface is dirty or burnt, correct it with sandpaper (No. 400) or a lathe.

If necessary, replace the starter armature assembly.


b.

Inspect the commutator for an open circuit.

i.
A215965E01
2.709,1.219 3.300,1.361 0.591,0.142 10 Segment 0.652,1.614 1.243,1.756 0.591,0.142 10 Segment 1.392,1.69 1.494,1.69 1.494,1.69 1.993,1.168 false 2.657,1.305 2.577,1.305 2.577,1.305 2.187,0.891 false

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Segment - Segment Always Below 1 Ω


If the result is not as specified, replace the starter armature assembly.



c.

Inspect the commutator for a short circuit.

i.
A215966E08
2.542,1.688 2.479,1.688 2.479,1.688 2.063,1.208 false 0.771,0.802 0.844,0.802 0.844,0.802 1.292,1.115 false 2.594,1.604 3.198,1.76 0.604,0.156 10 false Segment 0.167,0.719 0.781,0.865 0.615,0.146 10 false Coil Core

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Segment - Coil core Always 10 kΩ or higher


If the result is not as specified, replace the starter armature assembly.



d.

Check the commutator circle runout.

i.

Place the armature shaft on V-blocks.


ii.
A215967

Using a dial indicator, measure the circle runout.

Maximum runout:

0.05 mm (0.00197 in.)


If the circle runout is more than the maximum, replace the starter armature assembly.



e.
A215958

Using a vernier caliper, measure the commutator diameter.

Standard diameter:

29.0 mm (1.14 in.)


Minimum diameter:

28.0 mm (1.10 in.)


HINT:

Be sure to measure the commutator diameter at the ridges.


If the diameter is less than the minimum, replace the starter armature assembly.


f.
A062965

Check that the undercut portion is clean and free of foreign matter. Smooth out the edge.

Standard undercut depth:

0.4 mm (0.0157 in.)


Minimum undercut depth:

0.2 mm (0.00787 in.)


HINT:

Be sure to measure the commutator undercut depth at a cutout.


If the undercut depth is less than the minimum, increase the depth using a hacksaw blade.


Hide 4.INSPECT STARTER BRUSH HOLDER ASSEMBLY

a.
A215975

Using a vernier caliper, measure the brush length.

Standard length:

14.4 mm (0.567 in.)


Minimum length:

9.0 mm (0.354 in.)


HINT:

Be sure to measure the brush lengths at the protrusions.


If the length is less than the minimum, replace the starter brush holder assembly.


b.

Inspect the load of the brush spring.

i.
ST00019E19
2.396,1.375 3.219,1.563 0.823,0.188 10 false Brush Spring 0.844,1.646 1.24,1.802 0.396,0.156 10 false Brush

Take a pull scale reading immediately after the brush spring separates from the brush.

Standard spring load:

22 to 27 N (2 to 3 kgf, 5.0 to 6.1 lbf)


Minimum spring load:

14 N (1 kgf, 3.1 lbf)


If the load is less than the minimum, replace the starter brush holder assembly.



Hide 28021 5.INSPECT STARTER CENTER BEARING CLUTCH SUB-ASSEMBLY

a.

Check the gear teeth on the planetary gears, and the internal gear and pinion gear of the starter center bearing clutch for wear or damage.

If any of the gears is damaged, replace the gear or starter center bearing clutch sub-assembly.


b.
A215964E05
1.281,1.542 1.625,1.688 0.344,0.146 10 false Lock 1.698,0.281 2.021,0.427 0.323,0.146 10 false Free

Hold the starter clutch, rotate the pinion gear clockwise and check that it turns freely. Try to rotate the pinion gear counterclockwise and check that it locks.

If the result is not as specified, replace the starter center bearing clutch sub-assembly.