The ATF temperature sensor converts the fluid temperature into a resistance value for use by the ECM.
The ECM applies a voltage to the temperature sensor through terminal THO1 of the ECM.
The sensor resistance changes with the ATF temperature. As the temperature becomes higher, the sensor resistance decreases.
One terminal of the sensor is grounded so that the sensor resistance decreases and the voltage goes down as the temperature becomes higher.
The ECM calculates the fluid temperature based on the voltage signal.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0712 | ATF temperature sensor resistance is below 79 Ω for 0.5 sec. or more (1 trip detection logic) | ·
Short in ATF temperature sensor circuit ·
ATF temperature sensor ·
ECM |
| P0713 | ATF temperature sensor resistance is higher than 156 kΩ for 0.5 sec. or more either of the following conditions is met (1 trip detection logic):
(A) 388 sec. or more have elapsed after the engine start when engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less. (B) 10 sec. or more have elapsed after the engine start when engine coolant temperature and intake air temperature are higher than -29.375°C (-20.875°F). |
·
Open in ATF temperature sensor circuit ·
ATF temperature sensor ·
ECM |
The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the ECM determines the ATF temperature and detects an open or short in the ATF temperature sensor circuit. If the resistance value of the ATF temperature sensor is below 79 Ω*1 or higher than 156 kΩ*2, the ECM interprets this as a fault in the ATF temperature sensor or wiring. The ECM will illuminate the MIL and store the DTC.
*1: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.
*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.
The ATF temperature can be checked on the Techstream display.
| Related DTCs | P0712: ATF temperature sensor/Range check (Low voltage)
P0713: ATF temperature sensor/Range check (High voltage) |
| Required sensors/Components | ATF temperature sensor |
| Frequency of operation | Continuous |
| Duration | 0.5 seconds |
| MIL operation | Immediately |
| Sequence of operation | None |
| Battery voltage | 8 V or higher |
| Ignition switch | ON |
| Starter | OFF |
| The monitor will run whenever the following DTCs are not present | None |
One of the following conditions is met: Condition (A) or (B)
| The monitor will run whenever this DTC is not present | P0115, P0117, P0118 (ECT (Engine coolant temperature) sensor circuit)
P00AC, P00AD, P0110, P0112, P0113 (IAT (Intake air temperature) sensor circuit) |
| Engine coolant temperature or intake air temperature at engine start | -29.375°C (-20.875°F) or less |
| Time after engine start | 388 seconds or more |
| The monitor will run whenever this DTC is not present | P0115, P0117, P0118 (ECT (Engine coolant temperature) sensor circuit)
P00AC, P00AD, P0110, P0112, P0113 (IAT (Intake air temperature) sensor circuit) |
| Engine coolant temperature and intake air temperature at engine start | Higher than -29.375°C (-20.875°F) |
| Time after engine start | 10 seconds or more |
| ATF temperature sensor voltage | Below 0.14 V (Higher than 164°C (327.2°F)) |
| ATF temperature sensor voltage | Higher than 4.91 V (Below -48°C (-54.4°F)) |
| ATF temperature sensor voltage | 0.14 to 4.91 V |
Perform the universal trip to clear permanent DTCs (See page Drivetrain>AB60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).
DATA LIST
Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Warm up the engine.
Turn the ignition switch off.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the Techstream, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| A/T Oil Temperature 1 | No. 1 ATF temperature sensor value/
Min.: -40°C (-40°F) Max.: 150°C (302°F) |
·
After stall test: Approximately 80°C (176°F) ·
Equal to ambient temperature while engine is cold |
If value is -40°C (-40°F) or 150°C (302°F), No. 1 ATF temperature sensor circuit is open or shorted |
When DTC P0712 is output and the Techstream output is 150°C (302°F) or higher, there is a short circuit.
When DTC P0713 is output and the Techstream output is -40°C (-40°F), there is an open circuit.
Measure the resistance between terminal THO1 and the body ground.
| Temperature Displayed | Malfunction |
|---|---|
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or higher | Short circuit |
If a circuit related to the ATF temperature sensor becomes open, P0713 is immediately set (in 0.5 seconds). When P0713 is set, P0711 cannot be detected.
It is not necessary to inspect the circuit when P0711 is set.
Disconnect the D41 No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (OT-) - 9 (OT+) | Always | 79 Ω to 156 kΩ |
| 1 (OT-) - Body ground | Always | 10 kΩ or higher |
| 9 (OT+) - Body ground | Always | 10 kΩ or higher |
If the resistance is out of the specified range at one of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.
| ATF Temperature | Specified Condition |
|---|---|
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
OK
NG
Disconnect the D56 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D56-122 (THO1) - D56-98 (ETHA) | Always | 79 Ω to 156 kΩ |
| D56-122 (THO1) - Body ground | Always | 10 kΩ or higher |
| D56-98 (ETHA) - Body ground | Always | 10 kΩ or higher |
OK
NG