The amount of current flow to the solenoid is controlled by the ECM. During the lock-up operation, if the current increases, the lock-up hydraulic pressure increases.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| P2759 | Open or short is detected in shift solenoid valve SLU circuit for 1 second or more while driving (1 trip detection logic) | ·
Open or short in shift solenoid valve SLU circuit ·
Shift solenoid valve SLU ·
ECM |
When an open or short in a shift solenoid valve SLU circuit is detected, the ECM determines that there is a malfunction. The ECM will illuminate the MIL and store the DTC.
| Related DTCs | P2759: Shift solenoid valve SLU/Range check |
| Required sensors/Components | Shift solenoid valve SLU |
| Frequency of operation | Continuous |
| Duration | 1 second |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | None |
| Ignition switch | ON |
| Starter | OFF |
| Solenoid current cut status | Not cut |
| Battery voltage | 11 V or higher |
| Solenoid status from solenoid driver MIC | Fail |
| Output signal duty | Less than 100% |
Perform the universal trip to clear permanent DTCs (See page Drivetrain>AB60E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).
Disconnect the D41 No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 12 (SLU+) - 4 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 12 (SLU+) - Body ground | Always | 10 kΩ or higher |
| 4 (SLU-) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect the D56 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| D56-10 (SLU+) - D56-11 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| D56-10 (SLU+) - Body ground | Always | 10 kΩ or higher |
| D56-11 (SLU-) - Body ground | Always | 10 kΩ or higher |
OK
NG
Remove the shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Connect the battery positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
Valve moves and makes an operating noise.
OK
NG