Home › Drivetrain › JF3A TRANSFER / 4WD / AWD › TOUCH SELECT 2-4 AND HIGH-LOW SYSTEM
RM27L0U _52 Drivetrain _049312 JF3A TRANSFER / 4WD / AWD _0235671 TOUCH SELECT 2-4 AND HIGH-LOW SYSTEM U

JF3A TRANSFER / 4WD / AWD  TOUCH SELECT 2-4 AND HIGH-LOW SYSTEM  TERMINALS OF ECU  


CHECK 4WD CONTROL ECU


U153488E02
2.698,0.49 3,0.656 0.302,0.167 10 false A28 4.708,0.469 5.01,0.635 0.302,0.167 10 false A29

a.

Measure the voltage and resistance according to the value(s) in the table below.

Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
A28-1 (HL1) - A29-4 (GND) BE - W-B High-low transfer shift actuator limit switch Ignition switch ON
4WD control switch 4H
Below 1.5 V
Ignition switch ON
4WD control switch 4L
10.5 to 14 V
A28-2 (HL2) - A29-4 (GND) R - W-B High-low transfer shift actuator limit switch Ignition switch ON
4WD control switch 4H
10.5 to 14 V
Ignition switch ON
4WD control switch 4L
Below 1.5 V
A28-3 (HL3) - A29-4 (GND) GR - W-B High-low transfer shift actuator limit switch Ignition switch ON
4WD control switch 4H
10.5 to 14 V
Ignition switch ON
1.5 seconds or less after 4WD HIGH to 4WD LOW switching operation
Below 1.5 V
Ignition switch ON
Over 1.5 seconds after 4WD HIGH to 4WD LOW switching operation
10.5 to 14 V
A28-5 (TT) - A28-25 (TGND) L - P Temperature sensor Ignition switch ON 0 to 5 V
A28-6 (TL1) - A29-4 (GND) V - W-B Multi mode transfer shift actuator limit switch Ignition switch ON
4WD control switch 2WD
Below 1.5 V
Ignition switch ON
4WD control switch 4H or 4L
10.5 to 14 V
A28-7 (TL2) - A29-4 (GND) BR - W-B Multi mode transfer shift actuator limit switch Ignition switch ON
4WD control switch 2WD
10.5 to 14 V
Ignition switch ON
4WD control switch 4H or 4L
Center differential Lock
10.5 to 14 V
Ignition switch ON
4WD control switch 4H or 4L
Center differential Free
Below 1.5 V
A28-8 (TL3) - A29-4 (GND) W - W-B Multi mode transfer shift actuator limit switch Ignition switch ON
4WD control switch 2WD
10.5 to 14 V
Ignition switch ON
4WD control switch 4H or 4L
Center differential Lock
Below 1.5 V
Ignition switch ON
4WD control switch 4H or 4L
Center differential Free
10.5 to 14 V
A28-9 (DL1) - A29-4 (GND) LG - W-B A.D.D. actuator limit switch Ignition switch ON
4WD control switch 2WD (A.D.D. actuator Free)
10.5 to 14 V
Ignition switch ON
4WD control switch 4H (A.D.D. actuator Lock)
Below 1.5 V
A28-10 (DL2) - A29-4 (GND) R - W-B A.D.D. actuator limit switch Ignition switch ON
4WD control switch 2WD (A.D.D. actuator Free)
Below 1.5 V
Ignition switch ON
4WD control switch 4H (A.D.D. actuator Lock)
10.5 to 14 V
A28-11 (2-4) - A29-4 (GND) B - W-B 4WD control switch Ignition switch ON
4WD control switch 2WD or 4H
Below 1.5 V
Ignition switch ON
4WD control switch 4L
10.5 to 14 V
A28-12 (DL) - A29-4 (GND) GR - W-B Center differential lock switch Ignition switch ON
Center differential lock switch OFF
10.5 to 14 V
Ignition switch ON
Center differential lock switch ON
Below 1.5 V
A28-13 (LO) - A29-4 (GND) P - W-B 4WD control switch Ignition switch ON
4WD control switch 2WD
10.5 to 14 V
Ignition switch ON
4WD control switch 4H or 4L
Below 1.5 V
A28-14 (4WD) - A29-4 (GND) G - W-B Multi mode transfer shift actuator
center differential lock position detection switch
Ignition switch ON
4WD control switch 2WD
9.5 to 14 V
Ignition switch ON
4WD control switch 4H or 4L
Center differential Lock
Below 1.5 V
Ignition switch ON
4WD control switch 4H or 4L
Center differential Free
9.5 to 14 V
A28-15 (ADD) - A29-4 (GND) Y - W-B A.D.D. actuator A.D.D. detection switch Ignition switch ON
4WD control switch 2WD
10 to 14 V
Ignition switch ON
4WD control switch 4H or 4L
Below 1.5 V
A28-16 (NP) - A29-4 (GND) B - W-B Multi mode transfer shift actuator neutral detection switch Ignition switch ON
1.5 seconds or less after 4WD HIGH to 4WD LOW switching operation
Below 1.5 V
Ignition switch ON
Over 1.5 seconds after 4WD HIGH to 4WD LOW switching operation
10 to 14 V
A28-19 (CANH) - A28-20 (CANL) BE - W CAN communication line Ignition switch off 54 to 69 Ω
A28-21 (L4) - A29-4 (GND) Y - W-B Transfer 4LO signal Except 4WD control switch 4L 10 to 14 V
Ignition switch ON
4WD control switch 4L
Below 1.5 V
A29-1 (DM1) - A29-4 (GND) W - W-B A. D. D. actuator motor Ignition switch ON
4WD control switch 4H (During operation of A.D.D. actuator from Lock to Free)
10 to 14 V
Ignition switch ON
4WD control switch 4H (A.D.D. actuator Free)
Below 1.5 V
A29-2 (HM1) - A29-4 (GND) GR - W-B High-low transfer shift actuator motor Ignition switch ON
4WD control switch 4L → 4H (During operation of high-low transfer shift actuator motor from 4WD LOW to 4WD HIGH)
10 to 14 V
Ignition switch ON
4WD control switch 4L → 4H (High-low transfer shift actuator motor stopped)
Below 1.5 V
A29-3 (IG) - A29-4 (GND) V - W-B IG power Ignition switch ON 11 to 14 V
A29-4 (GND) - Body ground W-B - Body ground Ground Always Below 1 Ω
A29-5 (DM2) - A29-4 (GND) Y - W-B A. D. D. actuator motor Ignition switch ON
4WD control switch 4H (during operation of A.D.D. actuator from Free to Lock)
10 to 14 V
Ignition switch ON
4WD control switch 4H (A.D.D. actuator Lock)
Below 1.5 V
A29-6 (HM2) - A29-4 (GND) P - W-B High-low transfer shift actuator motor Ignition switch ON
4WD control switch 4H → 4L (During operation of high-low transfer shift actuator motor from 4WD HIGH to 4WD LOW)
10 to 14 V
Ignition switch ON
4WD control switch 4H → 4L (High-low transfer shift actuator motor stopped)
Below 1.5 V
A29-7 (TM2) - A29-4 (GND) LG - W-B Multi mode transfer shift actuator motor Ignition switch ON
4WD control switch 4H or 4L → 2WD (During operation of Multi mode transfer shift actuator motor from 4WD HIGH or 4WD LOW to 2WD)
10 to 14 V
Ignition switch ON
4WD control switch 4H or 4L → 2WD (Multi mode transfer shift actuator motor stopped)
Below 1.5 V
A29-8 (TM1) - A29-4 (GND) R - W-B Multi mode transfer shift actuator motor Ignition switch ON
4WD control switch 2WD → 4H or 4L (During operation of Multi mode transfer shift actuator motor from 2WD to 4WD HIGH or 4WD LOW)
10 to 14 V
Ignition switch ON
4WD control switch 2WD → 4H or 4L (Multi mode transfer shift actuator motor stopped)
Below 1.5 V