41400
1.REMOVE AUTOMATIC DISCONNECTING DIFFERENTIAL ACTUATOR
Measure the resistance between terminals 1 and 2.
0.1 to 100 Ω
Measure the resistance between terminal 1 or 2 and body ground.
5 MΩ or more
If the result is not as specified, replace the differential motor actuator.
Check the actuator using one of the following methods.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Measurement Condition | Specified Condition |
|---|---|---|
| 3 (ADD) - 4(GND) | Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 | Below 1 Ω |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | 10 kΩ or higher | |
| 4 (GND) - 5 (DL2) | Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 | Below 1 Ω |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | 10 kΩ or higher | |
| 4 (GND) - 6 (DL1) | Battery positive (+) → Terminal 1 Battery negative (-) → Terminal 2 | Below 1 Ω |
| Battery positive (+) → Terminal 2 Battery negative (-) → Terminal 1 | 10 kΩ or higher |
| *1 | Shift Fork |
| *a | 2WD Side |
| *b | 4WD Side |
| *c | 12 mm (0.472 in.) |
If the result is not as specified, replace the differential motor actuator assembly.
Check the actuator status.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → Terminal 1
Battery negative (-) → Terminal 2 |
2WD → 4WD |
| Battery positive (+) → Terminal 2
Battery negative (-) → Terminal 1 |
4WD → 2WD |
If the result is not as specified, replace the differential motor actuator assembly.