89249
1.INSPECT HEIGHT CONTROL SWITCH (NO. 1 ABSORBER CONTROL SWITCH)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 4 (LSW) - 6 (E) | "Down" pressed | Below 1 Ω |
| Not pressed | 10 KΩ or higher | |
| 5 (HSW) - 6 (E) | "Up" pressed | Below 1 Ω |
| Not pressed | 10 KΩ or higher |
| *a | Component without harness connected
(Height Control Switch) |
If the result is not as specified, replace the height control switch (No. 1 absorber control switch).
89249D
2.INSPECT HEIGHT CONTROL MODE SELECT SWITCH (NO. 2 ABSORBER CONTROL SWITCH)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| 3 - 6 | Pressed | Below 1 Ω |
| Not pressed | 10 KΩ or higher |
| *a | Component without harness connected
(Height Control Mode Select Switch) |
If the result is not as specified, replace the height control mode select switch (No. 2 absorber control switch).