86160U
1.INSPECT QUARTER SIDE SPEAKER ASSEMBLY (for 8 or 12 Speakers)
When there is a malfunction such as noise from a speaker or no sound at all, replace the speaker with a new one and check that the malfunction disappears.
Malfunction disappears.
Connect the connectors to the quarter side speakers.
When there is a possibility that either the right or left quarter side speaker assembly is defective, inspect by interchanging the right one with the left one.
Perform the inspection above on both the LH and RH sides.
86160U
2.INSPECT QUARTER SIDE SPEAKER ASSEMBLY (for 14 Speakers)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Always | 1.5 to 2.5 Ω |
If the result is not as specified, replace the quarter side speaker assembly.
| *a | Component without harness connected
(Quarter Side Speaker Assembly) |
86150
3.INSPECT W/BOX NO. 1 SPEAKER ASSEMBLY (for 14 Speakers)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | Always | 1.6 to 2.4 Ω |
| 3 - 4 | Always | 1.6 to 2.4 Ω |
If the result is not as specified, replace the w/box No. 1 speaker assembly.
| *a | Component without harness connected
(w/box No. 1 Speaker Assembly) |