AIR CONDITIONING AMPLIFIER
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H67-6 (SG-5) - Body ground | BR - Body ground | Ground | Always | Below 1 Ω |
| H67-8 (S5-2) - Body ground | SB - Body ground | Power supply | Ignition switch ON | 4.5 to 5.5 V |
| H67-9 (SHD+) - Body ground | W - Body ground | Output climate control signal (Driver side) | Ignition switch ON
Seat heater switch blower side volume 3 |
Pulse generation
(see waveform 1) |
| H67-10 (SHP+) - Body ground | BE - Body ground | Output climate control signal (Front passenger side) | Ignition switch ON
Seat heater switch blower side volume 3 |
Pulse generation
(see waveform 1) |
| H67-15 (AD-4) - Body ground | GR - Body ground | Input climate control signal (Driver side) | Ignition switch ON
Seat heater switch volume 0 |
4.5 to 5.5 V |
| Ignition switch ON
Seat heater switch blower side volume 3 |
Below 1 V | |||
| H67-16 (AD-5) - Body ground | W - Body ground | Input climate control signal (Front passenger side) | Ignition switch ON
Seat heater switch volume 0 |
4.5 to 5.5 V |
| Ignition switch ON
Seat heater switch blower side volume 3 |
Below 1 V |
If the result is not as specified, the air conditioning amplifier may have a malfunction.
Waveform 1: Using an oscilloscope:
| Terminal No. (Symbol) | Tool setting | Condition |
|---|---|---|
| H67-9 (SHD+) - Body ground
H67-10 (SHP+) - Body ground |
2 V/DIV., 500 μsec/DIV. | Ignition switch ON
Seat heater switch blower side volume 3 |