CHECK AIR CONDITIONING AMPLIFIER
Disconnect the H24, H67 and z13 air conditioning amplifier connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H24-1 (IG+) - Body ground | P - Body ground | Ignition power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| H24-14 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| H24-21 (B) - Body ground | R - Body ground | Battery power source | Always | 11 to 14 V |
| H67-20 (RGND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| H67-24 (+B2) - Body ground | LG - Body ground | Battery power source | Always | 11 to 14 V |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the H24, H67 and z13 air conditioning amplifier connectors.
Measure the voltage and resistance according to the value(s) in the table below.
Check from the rear of the connector with it connected to the air conditioning amplifier.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H24-5 (TAM) - H24-13 (SG-2) | V - G | A/C ambient temperature sensor signal | Ignition switch ON at 25°C (77°F) | 1.35 to 1.75 V |
| Ignition switch ON at 40°C (104°F) | 0.9 to 1.2 V | |||
| H24-8 (LOCK) - H24-13 (SG-2) | SB - G | A/C compressor lock sensor signal | Engine is running
Blower switch LO A/C switch ON |
Pulse generation
(see waveform 1) |
| H24-9 (PRE) - Body ground | Y - Body ground | A/C pressure sensor signal | Refrigerant pressure: normal | 0.5 to 4.8355 V |
| H24-10 (S5-3) - Body ground | R - Body ground | Power supply for pressure sensor | Ignition switch ON | 4.5 to 5.5 V |
| H24-11 (CANH) - H24-14 (GND) | B - W-B | Hi-level CAN bus line | Ignition switch ON | Pulse generation
(see waveform 2) |
| H24-12 (CANL) - H24-14 (GND) | W - W-B | Lo-level CAN bus line | Ignition switch ON | Pulse generation
(see waveform 3) |
| H24-13 (SG-2) - Body ground | G - Body ground | Ground for ambient temperature sensor | Always | Below 1 Ω |
| H24-17 (AC1) - H24-14 (GND) | B - W-B | Idle-up request signal | Engine idling
Magnet Clutch is not engaged |
11 to 14 V |
| Engine idling
Magnet Clutch is engaged |
Below 1 V | |||
| H24-18 (MHTR) - H24-14 (GND) | L - W-B | Mirror heater relay drive signal | Mirror heater switch OFF→ON | 11 to 14 V → Below 1 V |
| H24-20 (MGC) - H24-14 (GND) | P - W-B | A/C compressor magnetic clutch operation signal | Ignition switch ON
Blower switch LO A/C switch OFF |
11 to 14 V |
| Ignition switch ON
Blower switch LO A/C switch ON |
Below 1 V | |||
| H24-23 (BLW) - H24-14 (GND) | LG - W-B | Blower motor control signal | Ignition switch ON
Blower switch LO |
Pulse generation
(see waveform 4) |
| H24-27 (ACT) - H24-14 (GND) | L - W-B | A/C compressor magnetic clutch on permit signal | Engine idling → Accelerator pedal depressed (Air conditioning cut signal output when engine load increases rapidly) | 11 to 14 V → Below 2 V |
| H24-29 (TR) - H24-34 (SG-1) | G - B | Room temperature sensor signal | Ignition switch ON
Front side interior temperature: 25°C (77°F) |
1.8 to 2.2 V |
| H24-32 (TSP) - Body ground | L - Body ground | Passenger side solar sensor signal | Ignition switch ON
Solar sensor subjected to electric light |
0.8 to 4.3 V |
| H24-33 (TSD) - Body ground | P - Body ground | Driver side solar sensor signal | Ignition switch ON
Solar sensor subjected to electric light |
0.8 to 4.3 V |
| H24-34 (SG-1) - Body ground | B - Body ground | Ground for room temperature sensor | Always | Below 1 Ω |
| H24-37 (LIN1) - H24-14 (GND) | SB - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
| H24-38 (RDEF) - H24-14 (GND) | R - W-B | Defogger relay drive signal | Defogger switch OFF→ON | 11 to 14 V → Below 1 V |
| H24-39 (CFN+) - H24-14 (GND) | V - W-B | Condenser fan relay drive signal | Ignition switch ON
Condenser fan OFF→ON |
11 to 14 V → Below 1 V |
| H24-40 (D) - H24-14 (GND) | GR - W-B | Deicer relay drive signal | Deicer switch OFF→ON | 11 to 14 V → Below 1 V |
| H67-1 (RBUS) - H67-21 (RBUG) | V - G | BUS IC control signal | Ignition switch off → ON | Pulse generation |
| H67-4 (TEC) - H67-19 (SGND) | R - L | Rear evaporator temperature sensor signal | Ignition switch ON
Evaporator temperature at 0°C (32°F) |
1.7 to 2.1 V |
| H67-6 (SG-5) - Body ground | BR - Body ground | Ground for seat blower switch | Always | Below 1 Ω |
| H67-7 (SG-6) - Body ground | P - Body ground | Ground for rear room temperature sensor | Always | Below 1 Ω |
| H67-8 (S5-2) - H67-6 (SG-5) | SB - BR | Power supply for seat blower switch | Ignition switch ON | 4.5 to 5.5 V |
| H67-9 (SHD+) - H67-20 (RGND) | W - W-B | Driver seat blower drive signal | Ignition switch ON | Pulse generation |
| H67-10 (SHP+) - H67-20 (RGND) | BE - W-B | Passenger seat blower drive signal | Ignition switch ON | Pulse generation |
| H67-13 (RLIN) - H67-20 (RGND) | B - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
| H67-15 (AD-4) - H67-20 (RGND) | GR - W-B | Driver seat blower switch signal | Ignition switch ON
Driver seat blower switch 0 position |
4.5 to 5.5 V |
| Ignition switch ON
Driver seat blower switch 3 position |
Below 1 V | |||
| H67-16 (AD-5) - H67-20 (RGND) | W - W-B | Passenger seat blower switch signal | Ignition switch ON
Passenger seat blower switch 0 position |
4.5 to 5.5 V |
| Ignition switch ON
Passenger seat blower switch 3 position |
Below 1 V | |||
| H67-17 (TR) - H67-7 (SG-6) | L - P | Rear room temperature sensor signal | Ignition switch ON
Rear side interior temperature: 25°C (77°F) |
1.8 to 2.2 V |
| H67-19 (SGND) - Body ground | L - Body ground | Ground for rear evaporator temperature sensor | Always | Below 1 Ω |
| H67-21 (RBUG) - Body ground | G - Body ground | Ground for BUS IC | Always | Below 1 Ω |
| H67-22 (BLWH) - H67-20 (RGND) | P - W-B | Blower motor control signal | Ignition switch ON
Blower switch LO |
Pulse generation
(see waveform 5) |
| H67-23 (RBBU) - H67-21 (RBUG) | Y - G | Power supply for BUS IC | Ignition switch off | Below 1 V |
| Ignition switch ON | 11 to 14 V | |||
| z13-2 (BUS G) - Body ground | - | Ground for BUS IC | Always | Below 1 Ω |
| z13-3 (BUS) - z13-2 (BUS G) | - | BUS IC control signal | Ignition switch off → ON | Pulse generation |
| z13-4 (B BUS) - z13-2 (BUS G) | - | Power supply for BUS IC | Ignition switch off | Below 1 V |
| z13-4 (B BUS) - z13-2 (BUS G) | - | Ignition switch ON | 11 to 14 V | |
| z13-5 (SGA) - Body ground | - | Ground for evaporator temperature sensor | Always | Below 1 Ω |
| z13-6 (TEA) - z13-5 (SGA) | - | A/C evaporator temperature sensor signal | Ignition switch ON
Evaporator temperature at 0°C (32°F) |
1.7 to 2.1 V |
| z13-6 (TEA) - z13-5 (SGA) | - | Ignition switch ON
Evaporator temperature at 15°C (59°F) |
0.7 to 1.3 V |
If the result is not as specified, the ECU may have a malfunction.
Waveform 1: Using an oscilloscope
| Terminal Name | LOCK - SG-2 |
| Tester Range | 200 mV/DIV., 10 ms./DIV. |
| Condition | Engine is running
Blower switch LO A/C switch ON |
Waveform 2 (Reference) : Using an oscilloscope
| Terminal Name | CANH - GND |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Ignition switch ON |
The waveform varies depending on the CAN communication signal.
Waveform 3 (Reference) : Using an oscilloscope
| Terminal Name | CANL - GND |
| Tester Range | 1 V/DIV., 10 μsec./DIV. |
| Condition | Ignition switch ON |
The waveform varies depending on the CAN communication signal.
Waveform 4 : Using an oscilloscope
| Terminal Name | BLW - GND |
| Tester Range | 1 V/DIV., 500 μsec./DIV. |
| Condition | Ignition switch ON
Blower switch LO |
When the blower level is increased, the duty ratio changes accordingly.
Waveform 5 : Using an oscilloscope
| Terminal Name | BLWH - RGND |
| Tester Range | 1 V/DIV., 500 μsec./DIV. |
| Condition | Ignition switch ON
Blower switch LO |
When the blower level is increased, the duty ratio changes accordingly.
CHECK INTEGRATION CONTROL AND PANEL
Disconnect the H45 integration control and panel connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H45-16 (IG+) - H45-1 (GND) | P - W-B | Ignition power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| H45-1 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the H45 integration control and panel connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| H45-3 (STX) - H45-1 (GND) | SB - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
If the result is not as specified, the integration control and panel may have a malfunction.
CHECK AIR CONDITIONING CONTROL PANEL
Disconnect the S4 air conditioning control panel connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| S4-1 (IG) - S4-4 (E) | P - W-B | Ignition power supply | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |||
| S4-4 (E) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
If the result is not as specified, there may be a malfunction on the wire harness side.
Reconnect the S4 air conditioning control panel connector.
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| S4-5 (RLIN) - S4-4 (E) | GR - W-B | LIN communication signal | Ignition switch ON | Pulse generation |
If the result is not as specified, the air conditioning control panel may have a malfunction.