Home › Vehicle Interior › HEATING / AIR CONDITIONING › REAR EVAPORATOR TEMPERATURE SENSOR
RM27L0U _58 Vehicle Interior _049344 HEATING / AIR CONDITIONING _0235906 REAR EVAPORATOR TEMPERATURE SENSOR G

HEATING / AIR CONDITIONING  REAR EVAPORATOR TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 82210L 1.INSPECT REAR EVAPORATOR TEMPERATURE SENSOR (NO. 2 AIR CONDITIONING HARNESS ASSEMBLY)

E345194E02
0.75,1.583 1.24,1.073 false 2.5,2.698 2.458,2.167 true 2.594,2.698 2.833,2.167 true 0.552,0.135 3.01,0.875 2.458,0.74 10 false Component without harness connected: (Rear Evaporator Temperature Sensor (No. 2 Air Conditioning Harness)) 1.313,0.969 3.385,1.542 2.073,0.573 10 false Rear Evaporator Sensor Area 2.271,2.052 2.729,2.25 0.458,0.198 10 false (+) 2.875,2.042 3.302,2.24 0.427,0.198 10 false (-) 4.208,0.292 6.5,0.49 2.292,0.198 10 false Resistance (kΩ) 4.156,0.979 4.771,1.177 0.615,0.198 10 false 10.0 4.229,1.156 4.771,1.354 0.542,0.198 10 false 9.0 4.229,1.354 4.771,1.563 0.542,0.208 10 false 8.0 4.229,1.531 4.771,1.719 0.542,0.188 10 false 7.0 4.229,1.708 4.76,1.906 0.531,0.198 10 false 6.0 4.229,1.885 4.771,2.083 0.542,0.198 10 false 5.0 4.229,2.063 4.781,2.271 0.552,0.208 10 false 4.0 4.229,2.25 4.792,2.458 0.563,0.208 10 false 3.0 4.229,2.427 4.781,2.625 0.552,0.198 10 false 2.0 4.229,2.615 4.771,2.823 0.542,0.208 10 false 1.0 4.229,2.792 4.781,3 0.552,0.208 10 false 0.0 4.333,2.979 4.792,3.177 0.458,0.198 10 false -10 4.99,2.99 5.396,3.188 0.406,0.198 10 false 0 5.542,2.99 5.979,3.188 0.438,0.198 10 false 10 6.135,2.99 6.552,3.198 0.417,0.208 10 false 20 6.646,2.99 7.104,3.188 0.458,0.198 10 false 30 4.313,3.167 4.927,3.365 0.615,0.198 10 false (14) 4.917,3.167 5.531,3.365 0.615,0.198 10 false (32) 5.51,3.167 6.125,3.365 0.615,0.198 10 false (50) 6.104,3.167 6.719,3.365 0.615,0.198 10 false (68) 6.604,3.167 7.156,3.354 0.552,0.188 10 false (86) 4.781,3.406 6.094,3.635 1.313,0.229 10 false Temperature °C (°F)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (-) - 8 (+) -10°C (14°F) 7.30 to 9.10 kΩ
7 (-) - 8 (+) -5°C (23°F) 5.65 to 6.95 kΩ
7 (-) - 8 (+) 0°C (32°F) 4.40 to 5.35 kΩ
7 (-) - 8 (+) 5°C (41°F) 3.40 to 4.15 kΩ
7 (-) - 8 (+) 10°C (50°F) 2.70 to 3.25 kΩ
7 (-) - 8 (+) 15°C (59°F) 2.14 to 2.58 kΩ
7 (-) - 8 (+) 20°C (68°F) 1.71 to 2.05 kΩ
7 (-) - 8 (+) 25°C (77°F) 1.38 to 1.64 kΩ
7 (-) - 8 (+) 30°C (86°F) 1.11 to 1.32 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


If the resistance value is not as specified, replace the sensor.