84794A
1.INSPECT FRONT WIPER DEICER RELAY
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | When battery voltage not applied | 10 kΩ or higher |
| 3 - 5 | Apply battery voltage to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the front wiper deicer relay.
85912
2.INSPECT DEFOGGER RELAY
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | When battery voltage is not applied | Below 1 Ω |
| 3 - 4 | When battery voltage applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | When battery voltage is not applied | 10 kΩ or higher |
| 3 - 5 | When battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the defogger relay.