DTC P0230 Fuel Pump Primary Circuit |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0230 | Open or short in FUEL PUMP relay circuit (1 trip detection logic) |
|

| 1.PERFORM ACTIVE TEST USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to the ON position and turn the Techstream ON.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Fuel Pump / Speed.
Check the operation of the relay while operating it using the Techstream.
|
| ||||
| NG | |
| 2.INSPECT RELAY (FUEL PUMP RELAY) |
![]() |
Remove the FUEL PUMP relay from the engine room junction block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| 3 - 4 | Below 1 Ω |
| 3 - 5 | 10 kΩ or higher |
| 3 - 4 | 10 kΩ or more (when battery voltage is applied to terminals 1 and 2) |
| 3 - 5 | Below 1 Ω (when battery voltage is applied to terminals 1 and 2) |
Reinstall the FUEL PUMP relay.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (FUEL PUMP RELAY - ECM) |
![]() |
Remove the FUEL PUMP relay from the engine room junction block.
Disconnect the E11 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Specified Condition |
| FUEL PUMP relay terminal 1 - FPR (E11-30) | Below 1 Ω |
| FUEL PUMP relay terminal 1 or FPR (E11-30) - Body Ground | 10 kΩ or higher |
Reconnect the ECM connector.
Reinstall the FUEL PUMP relay.
|
| ||||
| OK | ||
| ||