AUTOMATIC TRANSAXLE SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position.
Turn on the tester.
Select the item Powertrain / Engine and ECT / Data List.
According to the display on the tester, read the "Data List".
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Stop Light Switch | Stop light switch Status/ ON or OFF |
| - |
| Neutral Position SW signal | PNP switch Status/ ON or OFF | Shift lever position is; P and N: ON Except P and N: OFF | When the shift lever position displayed on Techstream differs from the actual position, adjustment of the PNP switch or the shift cable may be incorrect.
|
| Shift SW Status (P Range) | PNP switch Status/ ON or OFF | Shift lever position is: P: ON Except P: OFF | ↑ |
| Shift SW Status (N Range) | PNP switch Status/ ON or OFF | Shift lever position is: N: ON Except N: OFF | ↑ |
| Shift SW Status (R Range) | PNP switch Status/ ON or OFF | Shift lever position is; R: ON Except R: OFF | ↑ |
| Shift SW Status (D Range) | PNP switch Status/ ON or OFF | Shift lever position is; D and 4: ON Except D and 4: OFF | ↑ |
| Shift SW Status (2 Range) | PNP SW Status/ ON or OFF | Shift lever position is; 2 and L: ON Except 2 and L: OFF | ↑ |
| Shift SW Status (L Range) | PNP SW Status/ ON or OFF | Shift lever position is; L: ON Except L: OFF | ↑ |
| Shift SW Status (4 or D) | PNP SW Status/ ON or OFF | Shift lever position is; 4: ON Except 4: OFF | ↑ |
| Shift SW Status (3 Range) | PNP SW Status/ ON or OFF | Shift lever position is; 3: ON Except 3: OFF | ↑ |
| Shift SW Status | Actual Gear Position/ 1st, 2nd, 3rd, 4th or 5th (O/D) | Shift lever position is;
| - |
| Lock Up | Lock Up Status/ ON or OFF |
| - |
| Lock Up Solenoid Status | Lock Up Solenoid Status/ ON or OFF |
| - |
| SLT Solenoid Status | Shift Solenoid SLT Status/ ON or OFF |
| - |
| A/T Oil Temperature 1 | ATF Temp. Sensor Value/ min.: -40°C (-40°F) max.: 215°C (419°F) |
| If the value is "-40°C (-40°F)" or "215°C (419°F)", ATF temp. sensor circuit is opened or shorted. |
| SPD (NC) | Counter Gear Speed/ display: 50 r/min |
| - |
| SPD (NT) | Input Turbine Speed/display: 50 r/min |
| - |
| ACTIVE TEST |
Warm up the engine.
Turn the ignition switch off.
Connect Techstream to the DLC3.
Turn the ignition switch to the ON position.
Push the "ON" button of Techstream.
Select the item "Powertrain / Engine and ECT / Active Test".
According to the display on tester, perform the "Active Test".
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Control the Shift Position | [Test Details] Operate the shift solenoid valve and set the each shift position by yourself. [Vehicle Condition]
| 1st/2nd/3rd/4th/5th | Possible to check the operation of the shift solenoid valves. |
| Activate the Lock Up | [Test Details] Control the shift solenoid DSL to set the automatic transaxle to the lock-up condition. [Vehicle Condition]
| ON/OFF | Possible to check the DSL operation. |
| Activate the Solenoid (SL1) | [Test Details] Operate the shift solenoid SL1 [Vehicle Condition]
| ON/OFF | - |
| Activate the Solenoid (SL2) | [Test Details] Operate the shift solenoid SL2 [Vehicle Condition]
| ON/OFF | - |
| Activate the Solenoid (SL3) | [Test Details] Operate the shift solenoid SL3 [Vehicle Condition]
| ON/OFF | - |
| Activate the Solenoid (S4) | [Test Details] Operate the shift solenoid S4 [Vehicle Condition]
| ON/OFF | - |
| Activate the Solenoid (SR) | [Test Details] Operate the shift solenoid SR [Vehicle Condition]
| ON/OFF | - |
| Activate the Solenoid (DSL) | [Test Details] Operate the shift solenoid DSL [Vehicle Condition]
| ON/OFF | - |
| Activate the Solenoid (SLT)*
| [Test Details] Operate the shift solenoid SLT and raise the line pressure. [Vehicle Condition]
| ON/OFF | - |